• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Accuracy of Different Complete-Arch Digital Scanning Techniques with a Combined Healing Abutment-Scan Body System.
 

Accuracy of Different Complete-Arch Digital Scanning Techniques with a Combined Healing Abutment-Scan Body System.

Options
  • Details
Publisher DOI
10.11607/jomi.9209
PubMed ID
35235622
Description
PURPOSE

Investigate the effects of three different complete-arch digital implant scanning techniques used with a combined healing abutment-scan body (CHA-SB) system on the accuracy (trueness and precision) and scan time.

MATERIALS AND METHODS

A poly(methyl methacrylate) master model simulating an edentulous maxilla was fabricated with four parallelly inserted dental implants. A CHA-SB system was attached to each implant. The model surface was scanned using a structured blue light industrial extraoral scanner to achieve a reference model standard tessellation language file (MRM-STL). Three different scanning techniques-(1) conventional technique with unmodified master model, (2) scan body splinting technique using orthodontic elastic ligatures and plastic splint materials, and (3) land-marking technique using pyramid-shaped glass-ceramic markers-were performed. Fourteen consecutive digital scans were made by using an intraoral scanner (IOS) for each technique, converted to an STL file, and superimposed on the MRM-STL. Trueness and precision were calculated for each technique. The scan time was also recorded. The data were analyzed with one-way analysis of variance (ANOVA) and Tukey honest significant difference (HSD) tests (α = .05).

RESULTS

Effects of different scanning techniques on the trueness (distance and angular deviations; P < .001) and scan time (P = .002) were statistically significant. For precision, different scanning techniques had only a significant effect on the distance deviation (P < .001).

CONCLUSION

Regarding trueness and precision, none of the scanning techniques was superior to others. The scan body splinting technique led to significantly less scan time.
Date of Publication
2022
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Cakmak, Gülce
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Yilmaz, Hakan
Santos, Alejandro Treviño
Kökat, Ali Murat
Additional Credits
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Series
The international journal of oral & maxillofacial implants
Publisher
Quintessence Publishing
ISSN
1942-4434
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo