Publication:
A meta-analysis of the effect of stent design on clinical and radiologic outcomes of carotid artery stenting.

cris.virtualsource.author-orcid9cb37031-37cf-4639-8e9b-d969bed1ed54
datacite.rightsrestricted
dc.contributor.authorde Vries, Evelien E
dc.contributor.authorMeershoek, Armelle J A
dc.contributor.authorVonken, Evert J
dc.contributor.authorden Ruijter, Hester M
dc.contributor.authorVan den Berg, Josua Cornelis
dc.contributor.authorde Borst, Gert J
dc.date.accessioned2024-10-28T16:55:11Z
dc.date.available2024-10-28T16:55:11Z
dc.date.issued2019-06
dc.description.abstractOBJECTIVE Procedural characteristics, including stent design, may influence the outcome of carotid artery stenting (CAS). A thorough comparison of the effect of stent design on outcome of CAS is thus warranted to allow for optimal evidence-based clinical decision making. This study sought to evaluate the effect of stent design on clinical and radiologic outcomes of CAS. METHODS A systematic search was conducted in MEDLINE, Embase, and Cochrane databases in May 2018. Included were articles reporting on the occurrence of clinical short- and intermediate-term major adverse events (MAEs; any stroke or death) or radiologic adverse events (new ischemic lesions on postprocedural magnetic resonance diffusion-weighted imaging [MR-DWI], restenosis, or stent fracture) in different stent designs used to treat carotid artery stenosis. Random effects models were used to calculate combined overall effect sizes. Metaregression was performed to identify the effect of specific stents on MAE rates. RESULTS From 2654 unique identified articles, two randomized, controlled trials and 66 cohort studies were eligible for analysis (including 46,728 procedures). Short-term clinical MAE rates were similar for patients treated with open cell vs closed cell or hybrid stents. Use of an Acculink stent was associated with a higher risk of short-term MAE compared with a Wallstent (risk ratio [RR], 1.51; P = .03), as was true for use of Precise stent vs Xact stent (RR, 1.55; P < .001). Intermediate-term clinical MAE rates were similar for open vs closed cell stents. Use of open cell stents predisposed to a 25% higher chance (RR, 1.25; P = .03) of developing postprocedural new ischemic lesions on MR-DWI. No differences were observed in the incidence of restenosis, stent fracture, or intraprocedural hemodynamic depression with respect to different stent design. CONCLUSIONS Stent design is not associated with short- or intermediate-term clinical MAE rates in patients undergoing CAS. Furthermore, the division in open and closed cell stent design might conceal true differences in single stent efficacy. Nevertheless, open cell stenting resulted in a significantly higher number of subclinical postprocedural new ischemic lesions detected on MR-DWI compared with closed cell stenting. An individualized patient data meta-analysis, including future studies with prospective homogenous study design, is required to adequately correct for known risk factors and to provide definite conclusions with respect to carotid stent design for specific subgroups.
dc.description.numberOfPages10
dc.description.sponsorshipUniversitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie
dc.identifier.doi10.7892/boris.131292
dc.identifier.pmid31159989
dc.identifier.publisherDOI10.1016/j.jvs.2018.11.017
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/180775
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofJournal of vascular surgery
dc.relation.issn0741-5214
dc.relation.organizationDCD5A442BB1CE17DE0405C82790C4DE2
dc.subjectCarotid artery stenting MR-DWI Meta-analysis Stent design Stroke
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleA meta-analysis of the effect of stent design on clinical and radiologic outcomes of carotid artery stenting.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage1961.e1
oaire.citation.issue6
oaire.citation.startPage1952
oaire.citation.volume69
oairecerif.author.affiliationUniversitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2019-10-22 19:57:51
unibe.description.ispublishedpub
unibe.eprints.legacyId131292
unibe.journal.abbrevTitleJ VASC SURG
unibe.refereedtrue
unibe.subtype.articlereview

Files

Original bundle
Now showing 1 - 1 of 1
Name:
vandenberg_1-s2.0-S0741521418326508-main.pdf
Size:
804.71 KB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published

Collections