• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Fundamental aspects of field-amplified electrokinetic injection of cations for enantioselective capillary electrophoresis with sulfated cyclodextrins as selectors.
 

Fundamental aspects of field-amplified electrokinetic injection of cations for enantioselective capillary electrophoresis with sulfated cyclodextrins as selectors.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.116601
Publisher DOI
10.1016/j.chroma.2018.05.022
PubMed ID
29759647
Description
Head-column field-amplified sample stacking of cations from a low conductivity sample followed by enantiomeric separation using negatively charged chiral selectors was studied experimentally and with computer simulation. Aspects investigated include the direct electrokinetic injection of the analytes into the background electrolyte, the use of a selector free buffer plug, the contribution of complexation within the buffer plug and the application of an additional water plug between sample and buffer plug. Attention was paid for changes of ionic strength which is known to have a significant impact on complexation and thus effective mobility. Racemic methadone was selected as a model compound, randomly substituted sulfated β-cyclodextrin as chiral selector and phosphate buffers (pH 6.3) for the background electrolyte and the buffer plug. Results confirm that the buffer plug is providing a spacer between cationic analytes and the negatively charged selector during electrokinetic injection. Simulation predicts the required length and composition of the plug for a given injection time to avoid an interference with the selector. A short water plug added between the low conductivity sample and a high conductivity buffer plug is demonstrated to provide best conditions to achieve high sensitivity in enantioselective drug assays with sulfated cyclodextrins as selectors.
Date of Publication
2018-07-13
Publication Type
Article
Keyword(s)
Buffer plug Computer simulation Electrokinetic injection Enantioselective capillary electrophoresis Sulfated cyclodextrin Water plug
Language(s)
en
Contributor(s)
Sesták, Jozef
Institut für Infektionskrankheiten, Labor für Klinische Pharmakologie
Theurillat, Regula
Institut für Infektionskrankheiten, Labor für Klinische Pharmakologie
Sandbaumhüter, Friederike Andrea
Institut für Infektionskrankheiten, Labor für Klinische Pharmakologie
Thormann, Wolfgang
Institut für Infektionskrankheiten, Labor für Klinische Pharmakologie
Additional Credits
Institut für Infektionskrankheiten, Labor für Klinische Pharmakologie
Series
Journal of chromatography A
Publisher
Elsevier Science
ISSN
0021-9673
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo