  3. Control design for a lower-limb paediatric therapy device using linear motor technology
 

Control design for a lower-limb paediatric therapy device using linear motor technology

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.108590
Publisher DOI
10.1016/j.bspc.2017.05.011
Description
Background
Rehabilitation robots support delivery of intensive neuromuscular therapy and help patients to improve motor recovery. This paper describes the development and evaluation of control strategies for a novel lower-limb paediatric rehabilitation robot, based on linear-motor actuator technology and the leg-press exercise modality.

Methods
A functional model was designed and constructed and an overall control strategy was developed to facilitate volitional control of pedal position based on the cognitive task presented to the patient, together with automatic control of pedal forces using force feedback and impedance compensation.

Results
Each independent drive for the left and right legs can produce force up to 288 N at the user's foot. During dynamic testing, the user maintained a variable target position with root-mean-square tracking error (RMSE) of 3.8 ° with pure force control and 2.8 ° with combined force/impedance control, on a range of periodic motion of 20–80 °. With impedance compensation, accuracy of force tracking was also slightly better (RMSE of 9.3 vs. 9.8 N, force/impedance vs. force control only).

Conclusions
The control strategy facilitated accurate volitional control of pedal position and, simultaneously, accurate and robust control of pedal forces. Impedance compensation showed performance benefits. Control accuracy and force magnitude are deemed appropriate for rehabilitation of children with neurological impairments, but, due to current levels required, linear motor technology may not be suitable for applications where higher force is needed. Further work is required to validate the device within the target population of impaired children and to develop appropriate patient-interface software.
Date of Publication
2017-09
Publication Type
Article
Subject(s)
500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health
600 Technology > 620 Engineering
Language(s)
en
Contributor(s)
Chrif, Farouk
ARTORG Center for Biomedical Engineering Research
Nef, Tobiasorcid-logo
ARTORG - Gerontechnology and Rehabilitation
Lungarella, Max
Dravid, Raja
Hunt, Kenneth J.
Additional Credits
ARTORG Center for Biomedical Engineering Research
ARTORG - Gerontechnology and Rehabilitation
Series
Biomedical signal processing and control
Publisher
Elsevier
ISSN
1746-8094
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo