  3. An experimentally validated finite element method for augmented vertebral bodies
 

An experimentally validated finite element method for augmented vertebral bodies

Options
  • Details
Publisher DOI
10.1016/j.clinbiomech.2012.09.008
Description
Background

Finite element models of augmented vertebral bodies require a realistic modelling of the cement infiltrated region. Most methods published so far used idealized cement shapes or oversimplified material models for the augmented region. In this study, an improved, anatomy-specific, homogenized finite element method was developed and validated to predict the apparent as well as the local mechanical behavior of augmented vertebral bodies.

Methods

Forty-nine human vertebral body sections were prepared by removing the cortical endplates and scanned with high-resolution peripheral quantitative CT before and after injection of a standard and a low-modulus bone cement. Forty-one specimens were tested in compression to measure stiffness, strength and contact pressure distributions between specimens and loading-plates. From the remaining eight, fourteen cylindrical specimens were extracted from the augmented region and tested in compression to obtain material properties. Anatomy-specific finite element models were generated from the CT data. The models featured element-specific, density-fabric-based material properties, damage accumulation, real cement distributions and experimentally determined material properties for the augmented region. Apparent stiffness and strength as well as contact pressure distributions at the loading plates were compared between simulations and experiments.

Findings

The finite element models were able to predict apparent stiffness (R2 > 0.86) and apparent strength (R2 > 0.92) very well. Also, the numerically obtained pressure distributions were in reasonable quantitative (R2 > 0.48) and qualitative agreement with the experiments.

Interpretation

The proposed finite element models have proven to be an accurate tool for studying the apparent as well as the local mechanical behavior of augmented vertebral bodies.
Date of Publication
2013-01
Publication Type
Article
Subject(s)
500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health
600 Technology > 620 Engineering
Keyword(s)
Finite element
•
Vertebral body
•
Vertebroplasty
•
Augmentation
•
Bone cement
•
PMMA
Language(s)
en
Contributor(s)
Kinzl, Michael
Schwiedrzik, Johann Jakob
Institut für chirurgische Technologien und Biomechanik (ISTB)
Zysset, Philippeorcid-logo
Institut für chirurgische Technologien und Biomechanik (ISTB)
Pahr, Dieter H.
Additional Credits
Institut für chirurgische Technologien und Biomechanik (ISTB)
Series
Clinical biomechanics
Publisher
Elsevier
ISSN
0268-0033
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo