Publication:
Test-retest reliability and four-week changes in cardiopulmonary fitness in stroke patients: evaluation using a robotics-assisted tilt table

cris.virtual.author-orcid0000-0002-8069-9450
cris.virtualsource.author-orcid52b8d35e-faf4-4de5-88f6-9658f5f1c0f3
cris.virtualsource.author-orcid728825c5-dbc9-489d-9c1a-30a4770fc182
cris.virtualsource.author-orcid41aa2eb9-5e33-44f4-bffd-9aa4ede42580
datacite.rightsopen.access
dc.contributor.authorSaengsuwan, Jittima
dc.contributor.authorBerger, Livia
dc.contributor.authorSchuster-Amft, C
dc.contributor.authorNef, Tobias
dc.contributor.authorHunt, KJ
dc.date.accessioned2024-10-24T18:31:04Z
dc.date.available2024-10-24T18:31:04Z
dc.date.issued2016-09-06
dc.description.abstractBACKGROUND: Exercise testing devices for evaluating cardiopulmonary fitness in patients with severe disability after stroke are lacking, but we have adapted a robotics-assisted tilt table (RATT) for cardiopulmonary exercise testing (CPET). Using the RATT in a sample of patients after stroke, this study aimed to investigate test-retest reliability and repeatability of CPET and to prospectively investigate changes in cardiopulmonary outcomes over a period of four weeks. METHODS: Stroke patients with all degrees of disability underwent 3 separate CPET sessions: 2 tests at baseline (TB1 and TB2) and 1 test at follow up (TF). TB1 and TB2 were at least 24 h apart. TB2 and TF were 4 weeks apart. A RATT equipped with force sensors in the thigh cuffs, a work rate estimation algorithm and a real-time visual feedback system was used to guide the patients' exercise work rate during CPET. Test-retest reliability and repeatability of CPET variables were analysed using paired t-tests, the intraclass correlation coefficient (ICC), the coefficient of variation (CoV), and Bland and Altman limits of agreement. Changes in cardiopulmonary fitness during four weeks were analysed using paired t-tests. RESULTS: Seventeen sub-acute and chronic stroke patients (age 62.7 ± 10.4 years [mean ± SD]; 8 females) completed the test sessions. The median time post stroke was 350 days. There were 4 severely disabled, 1 moderately disabled and 12 mildly disabled patients. For test-retest, there were no statistically significant differences between TB1 and TB2 for most CPET variables. Peak oxygen uptake, peak heart rate, peak work rate and oxygen uptake at the ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) showed good to excellent test-retest reliability (ICC 0.65-0.94). For all CPET variables, CoV was 4.1-14.5 %. The mean difference was close to zero in most of the CPET variables. There were no significant changes in most cardiopulmonary performance parameters during the 4-week period (TB2 vs TF). CONCLUSIONS: These findings provide the first evidence of test-retest reliability and repeatability of the principal CPET variables using the novel RATT system and testing methodology, and high success rates in identification of VAT and RCP: good to excellent test-retest reliability and repeatability were found for all submaximal and maximal CPET variables. Reliability and repeatability of the main CPET parameters in stroke patients on the RATT were comparable to previous findings in stroke patients using standard exercise testing devices. The RATT has potential to be used as an alternative exercise testing device in patients who have limitations for use of standard exercise testing devices.
dc.description.sponsorshipARTORG - Gerontechnology and Rehabilitation
dc.description.sponsorshipUniversitätsklinik für Alterspsychiatrie und Psychotherapie (APP)
dc.identifier.doi10.7892/boris.90479
dc.identifier.pmid27600918
dc.identifier.publisherDOI10.1186/s12883-016-0686-0
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/146492
dc.language.isoen
dc.publisherBioMed Central
dc.relation.ispartofBMC neurology
dc.relation.issn1471-2377
dc.relation.organizationDCD5A442C49BE17DE0405C82790C4DE2
dc.relation.organizationDCD5A442C258E17DE0405C82790C4DE2
dc.relation.organizationDCD5A442BAE0E17DE0405C82790C4DE2
dc.relation.organizationDCD5A442C19EE17DE0405C82790C4DE2
dc.relation.organizationDCD5A442C783E17DE0405C82790C4DE2
dc.subjectCardiopulmonary exercise testing
dc.subjectRepeatability
dc.subjectRobotics-assisted tilt table; Stroke
dc.subjectTest-retest reliability
dc.subject.ddc500 - Science::570 - Life sciences; biology
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleTest-retest reliability and four-week changes in cardiopulmonary fitness in stroke patients: evaluation using a robotics-assisted tilt table
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.issue163
oaire.citation.startPage163
oaire.citation.volume16
oairecerif.author.affiliationARTORG - Gerontechnology and Rehabilitation
oairecerif.author.affiliationUniversitätsklinik für Alterspsychiatrie und Psychotherapie (APP)
oairecerif.author.affiliationARTORG - Gerontechnology and Rehabilitation
oairecerif.author.affiliation2Universitätsklinik für Alterspsychiatrie und Psychotherapie (APP)
oairecerif.author.affiliation3Universitätsklinik für Neurologie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.description.ispublishedpub
unibe.eprints.legacyId90479
unibe.journal.abbrevTitleBMC NEUROL
unibe.refereedtrue
unibe.subtype.articlejournal