  3. Impact of Adaptive Statistical Iterative Reconstruction-V on Coronary Artery Calcium Scores Obtained From Low-Tube-Voltage Computed Tomography - A Patient Study.
 

Impact of Adaptive Statistical Iterative Reconstruction-V on Coronary Artery Calcium Scores Obtained From Low-Tube-Voltage Computed Tomography - A Patient Study.

Options
  • Details
  • Files
BORIS DOI
10.48350/176411
Publisher DOI
10.1016/j.acra.2020.10.025
PubMed ID
33187851
Description
OBJECTIVE

To evaluate the impact of adaptive statistical iterative reconstruction-V (ASIR-V) on the accuracy of ultra-low-dose coronary artery calcium (CAC) scoring.

MATERIALS AND METHOD

One-hundred-and-three patients who underwent computed tomography (CT) for CAC scoring were prospectively included. All underwent standard scanning with 120-kilovolt-peak (kVp) and with 80- and 70-kVp tube voltage. ASiR-V was applied to the 80- and 70-kVp scans at different levels. The 120-kVp scans reconstructed with filtered back projection served as the standard of reference. Recently published novel kVp-adapted thresholds were used for calculation of CAC scores from 80- and 70-kVp scans and the resulting CAC scores were compared against the standard of reference. Patients were stratified into six CAC score risk categories: 0, 1-10, 11-100, 101-400, 401-1000, and >1000.

RESULTS

Increasing levels of ASIR-V led to an increasing underestimation of CAC scores with bias ranging from -128 to -118 and from -205 to -198 for the 80- and 70-kVp scans, respectively, when compared with the standard of reference. Reconstruction with 20% and 40% ASIR-V for the 80- and 70-kVp scans, respectively, yielded noise levels comparable to the standard of reference. Nevertheless, a change in risk-class was observed in 29 (28.6%) and 46 (44.7%) patients, exclusively to a lower risk-class, when CAC scores were derived from these reconstructions.

CONCLUSION

ASIR-V leads to noise reduction in CT scans acquired with low tube-voltages. However, ASIR-V introduces substantial inaccuracies and marked underestimation of ultra-low-dose CAC scoring as compared with standard-dose CAC scoring despite normalization of noise.
Date of Publication
2022-04
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Coronary artery calcium score adaptive statistical iterative reconstruction low tube voltage scans
Language(s)
en
Contributor(s)
Kamani, Christel H
Huang, Wenjie
Lutz, Joel
Giannopoulos, Andreas A
Patriki, Dimitri
von Felten, Elia
Schwyzer, Moritz
Gebhard, Catherine
Benz, Dominik C
Fuchs, Tobias A
Gräni, Christoph
Universitätsklinik für Kardiologie
Pazhenkottil, Aju P
Kaufmann, Philipp A
Buechel, Ronny R
Additional Credits
Universitätsklinik für Kardiologie
Series
Academic radiology
Publisher
Elsevier
ISSN
1076-6332
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo