MRI Metal Artifact Reduction Sequence for Auditory Implants: First Results with a Transcutaneous Bone Conduction Implant

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.130591
Publisher DOI
10.1159/000500513
PubMed ID
31067530
Description
Objective: Magnetic resonance imaging (MRI) is often limited in patients with auditory implants because of the presence of metallic components and magnets. The aim of this study was to evaluate the clinical usefulness of a customized MRI sequence for metal artifact suppression for patients with implants in the temporal bone region, specifically patients with a transcutaneous bone conduction implant.
Methods: Two whole head specimens were unilaterally implanted with a transcutaneous bone conduction implant. MRI examinations with and without a primarily self-build sequence (SEMAC-VAT WARP) for metal artifact suppression were performed. The diagnostic usefulness of the acquired MRI scans was rated independently by two neuroradiologists. The sequence was also used to acquire postimplantation follow-up MRI in a patient with a transcutaneous bone conduction implant.
Results: The customized SEMAC-VAT WARP sequence significantly improved the diagnostic usefulness of the postimplantation MRIs. The image acquisition time was 12 min and 20 s for the T1-weighted and 12 min and 12 s for the T2-weighted MRI. There was good agreement between the two blinded raters (Cohen’s κ = 0.61, p < 0.001).
Conclusion: The sequence for metal artifact reduction optimized in Bern enables MRI at 1.5 T in patients with active transcutaneous bone conduction implants without sacrificing diagnostic imaging quality. Particularly on the implanted side, imaging of intracranial and supra- and infratentorial brain pathologies is clinically more valuable than standard diagnostic MRI without any artifact reduction sequences.
Date of Publication
2019-05-08
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Wimmer, Wilhelmorcid-logo
Universitätsklinik für Hals-, Nasen- und Ohrenkrankheiten, Kopf- und Halschirurgie (HNOK)
ARTORG Center - Hearing Research Laboratory
Hakim, Arsany
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Kiefer, Claus
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Pastore-Wapp, Manuelaorcid-logo
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Anschütz, Lukas Peter
Universitätsklinik für Hals-, Nasen- und Ohrenkrankheiten, Kopf- und Halschirurgie (HNOK)
Caversaccio, Marco
Universitätsklinik für Hals-, Nasen- und Ohrenkrankheiten, Kopf- und Halschirurgie (HNOK)
ARTORG Center - Hearing Research Laboratory
Wagner, Franca
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Additional Credits
Universitätsklinik für Hals-, Nasen- und Ohrenkrankheiten, Kopf- und Halschirurgie (HNOK)
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Series
Audiology & Neurotology
Publisher
Karger
ISSN
1420-3030
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo