Publication:
[Irritation of the iliopsoas tendon after total hip arthroplasty]

cris.virtualsource.author-orciddfdf0758-46b5-4f7e-9787-350f9d4c27af
cris.virtualsource.author-orcid74a59b6d-b520-4482-a052-76e8f209bcdc
cris.virtualsource.author-orcid8aee5edd-6792-4c6c-96be-451af9ea3a51
datacite.rightsopen.access
dc.contributor.authorHessmann, M H
dc.contributor.authorHübschle, L
dc.contributor.authorTannast, Moritz
dc.contributor.authorSiebenrock, Klaus-Arno
dc.contributor.authorGanz, Reinhold
dc.date.accessioned2024-10-13T17:41:50Z
dc.date.available2024-10-13T17:41:50Z
dc.date.issued2007
dc.description.abstractChronic irritation of the iliopsoas tendon is a rare cause of persistent pain after total joint replacement of the hip. In the majority of cases, pain results from a mechanical conflict between the iliopsoas tendon and the anterior edge of the acetabular cup after total hip arthroplasty. Pain can be reproduced by active flexion of the hip and by active raising of the straightened leg. In addition, painful leg raising against resistance and passive hyperextension are suggestive of an irritation of the iliopsoas tendon. Symptoms evolve from a mechanical irritation of the iliopsoas tendon and an oversized or retroverted acetabular cup, screws penetrating into the inner aspect of the ilium, or from bone cement protruding beyond the anterior acetabular rim. The diagnosis may be assumed on conventional radiographs and confirmed by CT scans. Fifteen patients with psoas irritation after total hip replacement are reported on. Eleven patients were treated surgically. The acetabular cup was revised and reoriented with more anteversion in six patients, isolated screws penetrating into the tendon were cut and leveled in three patients, and prominent bone cement in conflict with the tendon was resected once. A partial release of the iliopsoas tendon only was performed in another patient. Follow-up examination (range: 11-89 months) revealed that nine patients were free of pain and two patient had mild residual complaints. Psoas irritation in combination with total hip replacement can be prevented by a correct surgical technique, especially with proper selection of the cup size and insertion of the acetabular cup avoiding a rim position exceeding the level of the anterior acetabular rim.
dc.description.numberOfPages6
dc.description.sponsorshipUniversitätsklinik für Orthopädische Chirurgie
dc.identifier.doi10.7892/boris.24446
dc.identifier.isi000248832800009
dc.identifier.pmid17541541
dc.identifier.publisherDOI10.1007/s00132-007-1094-3
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/98065
dc.language.isode
dc.publisherSpringer-Verlag
dc.publisher.placeHeidelberg
dc.relation.isbn17541541
dc.relation.ispartofOrthopäde
dc.relation.issn0085-4530
dc.relation.organizationDCD5A442BADEE17DE0405C82790C4DE2
dc.title[Irritation of the iliopsoas tendon after total hip arthroplasty]
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage51
oaire.citation.issue8
oaire.citation.startPage746
oaire.citation.volume36
oairecerif.author.affiliationUniversitätsklinik für Orthopädische Chirurgie
oairecerif.author.affiliationUniversitätsklinik für Orthopädische Chirurgie
oairecerif.author.affiliationUniversitätsklinik für Orthopädische Chirurgie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2019-10-23 06:42:52
unibe.description.ispublishedpub
unibe.eprints.legacyId24446
unibe.journal.abbrevTitleORTHOPADE
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
132_2007_Article_1094.pdf
Size:
686.39 KB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published

Collections