• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Comparison between a Flash Glucose Monitoring System and a Portable Blood Glucose Meter for Monitoring of Cats with Diabetic Ketosis or Ketoacidosis
 

Comparison between a Flash Glucose Monitoring System and a Portable Blood Glucose Meter for Monitoring of Cats with Diabetic Ketosis or Ketoacidosis

Options
  • Details
  • Files
BORIS DOI
10.48620/36367
Publisher DOI
https://doi.org/10.3390/ani14192787
PubMed ID
39409736
Description
Cats with diabetic ketosis or ketoacidosis DK(A) require intensive glucose monitoring. The aim of this study was to assess the agreement between a portable blood glucose meter (PBGM) and a flash glucose monitoring system (FGMS; FreeStyle Libre 2.0 Abbott®) measuring interstitial glucose in cats with DK(A). Ten client-owned cats with naturally occurring DK(A) were prospectively enrolled. Glucose concentrations were assessed with both methods every 1–3 h until resolution of DK(A), and every 4–8 h thereafter. While the median FGMS measured glucose concentration (14.3 mmol/L) was significantly lower than the median PBGM measured glucose concentration (19 mmol/L) (p < 0.001), the overall correlation between the FGMS and PBGM was high (r = 0.88; p < 0.001). In the Parkes error grid analysis, 98.3% of measurements fell in zones A and B. Bland–Altman plot analysis demonstrated that in the low glycaemic range (BG < 5.5 mmol/L), 50% of FGMS measurements deviated more than ±0.83 mmol/L, and in the high glycaemic range (BG ≥ 5.5 mmol/L), 81% of results deviated ≥15% from the PBGM measurements. There was significant inter-individual variation in the difference between glucose concentrations measured by the FGMS and PBGM (p < 0.001). In spite of being more easily tolerated and easier to use, currently this method cannot be recommended for routine monitoring of cats with DK(A).
Date of Publication
2024-09-26
Publication Type
Article
Keyword(s)
AlphaTRAK 2
•
FreeStyle Libre 2.0
•
feline diabetes
Language(s)
en
Contributor(s)
Eiermann, Jennifer S.
Small Animal Clinic
Department of Clinical Veterinary Medicine
Department of Clinical Veterinary Medicine, Small Animal Clinic, Internal Medicine
Katarina Hazuchova
Vidondo, Beatrizorcid-logo
Veterinary Public Health Institut (VPHI) - Epidemiologie
Veterinary Public Health Institute
Miguel Campos
Schuller, Simoneorcid-logo
Department of Clinical Veterinary Medicine, Small Animal Clinic, Internal Medicine
Small Animal Clinic
Department of Clinical Veterinary Medicine
Cui, Yi
Department of Clinical Veterinary Medicine, Small Animal Clinic, Internal Medicine
Small Animal Clinic
Additional Credits
Small Animal Clinic
Department of Clinical Veterinary Medicine, Small Animal Clinic, Internal Medicine
Veterinary Public Health Institute
Department of Clinical Veterinary Medicine
Veterinary Public Health Institut (VPHI) - Epidemiologie
Series
Animals
Publisher
Multidisciplinary Digital Publishing Institute (Switzerland)
ISSN
2076-2615
Related Funding(s)
ESVE Pilot Research Award
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo