• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Micro-Computed Tomographic Assessment of Microcrack Formation before and after Instrumentation of Curved Root Canals with Neoniti Rotary Files.
 

Micro-Computed Tomographic Assessment of Microcrack Formation before and after Instrumentation of Curved Root Canals with Neoniti Rotary Files.

Options
  • Details
  • Files
BORIS DOI
10.48350/170160
Publisher DOI
10.3390/ma15093002
PubMed ID
35591336
Description
The aim of this study was to assess the microcrack formation of moderately and severely curved root canals following instrumentation with Neoniti rotary files using micro-computed tomography. This in vitro study evaluated 18 extracted sound mandibular molars with two separate mesial canals and foramina in two groups (n = 9) with 5-20° (moderate) and 20-40° (severe) root canal curvature. The number of microcracks in the root canal walls was counted at baseline by micro-CT. Subsequently, the root canals were instrumented with 0.20/0.06 v Neoniti files as single files with a torque of 1.5 Ncm and a speed of 400 rpm. The number of microcracks was counted again postoperatively on micro-CT images using Amira software. Statistical analysis was performed using the Shapiro-Wilk test, Levene's test and repeated-measures ANOVA (α = 0.05). The mean number of microcracks significantly increased postoperatively in both the moderately curved (11.59 ± 9.74 vs. 8.2 ± 7.4; p = 0.001) and the severely curved (13.23 ± 5.64 vs. 7.20 ± 5.94; p < 0.001) groups. However, the differences between the two groups were not significant (p = 0.668). Based on the results obtained, it can be stated that the instrumentation of moderately and severely curved root canals with Neoniti rotary files increases the number of microcracks. However, the higher degree of curvature does not necessarily translate to a higher number of microcracks after root canal instrumentation with this specific rotary system and methodological procedures.
Date of Publication
2022-04-20
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Neoniti curved root micro-computed tomography microcrack root canal therapy
Language(s)
en
Contributor(s)
Zarean, Parichehr
Özcan, Mutlu
Zarean, Paridokht
Haghani, Seyed Omid
Jahromi, Maryam Zare
Al-Haj Husain, Nadin
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Khabiri, Masoud
Additional Credits
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Series
Materials
Publisher
MDPI
ISSN
1996-1944
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo