Publication:
Early versus newer generation devices for transcatheter aortic valve implantation in routine clinical practice: a propensity score matched analysis

cris.virtual.author-orcid0000-0002-8766-7945
cris.virtualsource.author-orcidb7cda86d-8924-42a5-973a-d73fee5c630b
cris.virtualsource.author-orcid31134751-5aa4-429b-82a9-a4f94bac9190
cris.virtualsource.author-orcid1ecd021c-6136-4235-88e2-2113af1457e8
cris.virtualsource.author-orcid987e86fe-121f-4490-8444-9a22622c19f7
cris.virtualsource.author-orcid6065cac3-a8d9-4720-8f5e-90e80751ce15
cris.virtualsource.author-orcidf066d906-a45d-4400-9e07-830bd9478529
cris.virtualsource.author-orcid304cd0e5-7737-49d2-ba51-e216e776ad30
cris.virtualsource.author-orcide58d604d-1e1c-4387-94ae-cf69dd2a3ea3
cris.virtualsource.author-orcid5c8247bd-3b6a-428b-a426-5f9725e9e9a4
cris.virtualsource.author-orcid45fdb777-ef57-4bb7-990e-313e4823f8aa
cris.virtualsource.author-orcid3fda0c3a-0cd0-438e-8e23-e3486ee2ffe0
cris.virtualsource.author-orcid4a27350f-3e6b-4727-83d5-66c789fad911
cris.virtualsource.author-orcidfe849ad6-0467-4f7d-b619-ebe55ba602a5
cris.virtualsource.author-orcid101f1394-72d5-4dda-b28f-666a3dee6c70
datacite.rightsopen.access
dc.contributor.authorPilgrim, Thomas
dc.contributor.authorLee, Joe K T
dc.contributor.authorO’Sullivan, Crochan J
dc.contributor.authorStortecky, Stefan
dc.contributor.authorAriotti, Sara
dc.contributor.authorFranzone, Anna
dc.contributor.authorLanz, Jonas
dc.contributor.authorHeg, Dierik Hans
dc.contributor.authorAsami, Masahiko
dc.contributor.authorPraz, Fabien Daniel
dc.contributor.authorSiontis, Georgios
dc.contributor.authorVollenbroich, René
dc.contributor.authorRäber, Lorenz
dc.contributor.authorValgimigli, Marco
dc.contributor.authorRoost, Eva
dc.contributor.authorWindecker, Stephan
dc.date.accessioned2024-10-25T13:38:48Z
dc.date.available2024-10-25T13:38:48Z
dc.date.issued2018-01-22
dc.description.abstractAbstract Aim Contemporary data comparing early versus newer generation transcatheter heart valve (THV) devices in routine clinical practice are lacking. We sought to compare the safety and efficacy of early versus newer generation THVs in unselected patients undergoing transcatheter aortic valve implantation (TAVI). Methods and results We performed a propensity score matched analysis of patients undergoing transfemoral TAVI at a single centre with early versus newer generation devices between 2007 and 2016. Patients were matched for balloon-expandable versus self-expandable valves and Society of Thoracic Surgeons score. The primary end point was the Valve Academic Research Consortium (VARC)-2 early safety composite end point at 30 days. Among the 391 matched pairs, no differences between early (21.2%) and newer generation (20.8%) THVs regarding the early safety composite end point (HR 0.98, 95% CI 0.72 to 1.33, P=0.88) were observed. The rates of valve embolisation (0.8% vs 4.2%, P=0.005), bleeding events (24.8% vs 32.0%, P=0.028) and moderate-to-severe paravalvular regurgitation (PVR) (3.1% vs 12.1%, P<0.001) were lower among patients receiving newer generation devices. Conversely, patients treated with early generation THVs less frequently experienced annulus rupture (0% vs 2.0%, P=0.008). Conclusion Newer compared with early generation THV devices were associated with a lower rate of valve embolisation, PVR and bleeding events.
dc.description.numberOfPages9
dc.description.sponsorshipUniversitätsklinik für Kardiologie
dc.description.sponsorshipClinical Trials Unit Bern (CTU)
dc.description.sponsorshipUniversitätsklinik für Herz- und Gefässchirurgie
dc.identifier.doi10.7892/boris.109921
dc.identifier.pmid29387427
dc.identifier.publisherDOI10.1136/openhrt-2017-000695
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/157450
dc.language.isoen
dc.publisherB M J Group
dc.relation.ispartofOpen Heart
dc.relation.issn2053-3624
dc.relation.organizationDCD5A442BB15E17DE0405C82790C4DE2
dc.relation.organizationDCD5A442BADFE17DE0405C82790C4DE2
dc.relation.organizationDCD5A442BE42E17DE0405C82790C4DE2
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleEarly versus newer generation devices for transcatheter aortic valve implantation in routine clinical practice: a propensity score matched analysis
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.issue1
oaire.citation.startPagee000695
oaire.citation.volume5
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationClinical Trials Unit Bern (CTU)
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Herz- und Gefässchirurgie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2019-10-25 18:41:19
unibe.description.ispublishedpub
unibe.eprints.legacyId109921
unibe.journal.abbrevTitleOpen Heart
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
Pilgrim OpenHeart 2018.pdf
Size:
1.01 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by-nc/4.0
Content:
published

Collections