• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Robust optimization and assessment of dynamic trajectory and mixed-beam arc radiotherapy: apreliminary study.

Robust optimization and assessment of dynamic trajectory and mixed-beam arc radiotherapy: apreliminary study.

Details
Files
DOI
10.48350/199405
Publisher DOI
10.1088/1361-6560/ad6950
PubMed ID
39079553
Abstract
Dynamic trajectory radiotherapy (DTRT) and dynamic mixed-beam arc therapy (DYMBARC) exploit non-coplanarity and, for DYMBARC, simultaneously optimized photon and electron beams. Margin concepts to account for set-up uncertainties during delivery are ill-defined for electron fields. We develop robust optimization for DTRT&DYMBARC and compare dosimetric plan quality and robustness for both techniques and both optimization strategies for four cases. Approach. Cases for different treatment sites and clinical target volume (CTV) to planning target volume (PTV) margins, m, were investigated. Dynamic gantry-table-collimator photon paths were optimized to minimize PTV/organ-at-risk (OAR) overlap in beam's-eye-view and minimize potential photon multileaf collimator (MLC) travel. For DYMBARC plans, non-isocentric partial electron arcs or static fields with shortened source-to-surface distance (80 cm) were added. Direct aperture optimization (DAO) was used to simultaneously optimize MLC-based intensity modulation for both photon and electron beams yielding deliverable PTV-based DTRT&DYMBARC plans. Robust-optimized plans used the same paths/arcs/fields. DAO with stochastic programming was used for set-up uncertainties with equal weights in all translational directions and magnitude δ such that m= 0.7δ. Robust analysis considered random errors in all directions with or without an additional systematic error in the worst 3D direction for the adjacent OARs. Main results. Electron contribution was 7%-41% of target dose depending on the case and optimization strategy for DYMBARC. All techniques achieved similar CTV coverage in the nominal (no error) scenario. OAR sparing was overall better in the DYMBARC plans than in the DTRT plans and DYMBARC plans were generally more robust to the considered uncertainties. OAR sparing was better in the PTV-based than in robust-optimized plans for OARs abutting or overlapping with the target volume, but more affected by uncertainties. Significance. Better plan robustness can be achieved with robust optimization than with margins. Combining electron arcs/fields with non-coplanar photon trajectories further improves robustness and OAR sparing.
Date Issued
2024-08-12
Publication Type
Article
Subject(s)
500 Science > 530 Physics
600 Technology > 610 Medicine & health
Subjects
Dynamic mixed-beam arc therapy Dynamic trajectory radiotherapy Robust optimization Robustness analysis
Language(s)
en
Author(s)
Bertholet, Jenny  
Universitätsklinik für Radio-Onkologie  
Universitätsklinik für Radio-Onkologie - Medizinische Strahlenphysik  
Guyer, Gian Mauro Carlo  
Universitätsklinik für Radio-Onkologie - Medizinische Strahlenphysik  
Müller, Silvan Andreas  
Universitätsklinik für Radio-Onkologie - Medizinische Strahlenphysik  
Löbner, Hannes Anton  
Universitätsklinik für Radio-Onkologie  
Volken, Werner  
Universitätsklinik für Radio-Onkologie - Medizinische Strahlenphysik  
Aebersold, Daniel Matthias  
Universitätsklinik für Radio-Onkologie  
Manser, Peter  
Universitätsklinik für Radio-Onkologie - Medizinische Strahlenphysik  
Fix, Michael  
Universitätsklinik für Radio-Onkologie - Medizinische Strahlenphysik  
Additional Credits
Universitätsklinik für Radio-Onkologie  
Universitätsklinik für Radio-Onkologie - Medizinische Strahlenphysik  
Journal
Physics in medicine and biology
Publisher
IOP Publishing
ISSN
1361-6560
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify