• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. The Supreme Biodegradable Polymer DES in Acute and Chronic Coronary Syndromes: A PIONEER III Substudy.
 

The Supreme Biodegradable Polymer DES in Acute and Chronic Coronary Syndromes: A PIONEER III Substudy.

Options
  • Details
  • Files
BORIS DOI
10.48620/77289
Publisher DOI
10.1016/j.jscai.2023.100629
PubMed ID
39130696
Description
Background
The PIONEER III trial demonstrated noninferiority of 12-month target lesion failure (TLF) with the Supreme DES (Sinomed), a thin-strut cobalt-chromium, biodegradable polymer, sirolimus-eluting stent, compared with a durable polymer, everolimus-eluting (XIENCE/PROMUS) stent (DP-EES). The relative safety and effectiveness of the Supreme DES in patients with acute coronary syndromes (ACS) and those with chronic coronary syndromes (CCS) is not known.Methods
PIONEER III was a prospective, multicenter, international, 2:1 randomized trial stratified by clinical presentation. The primary end point was TLF at 12 months (a composite of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization).Results
A total of 1628 patients were enrolled, including 41% of patients with ACS (unstable angina and non-ST-elevation myocardial infarction) randomized to Supreme DES (n = 441) versus DP-EES (n = 232) and 59% of patients with CCS randomized to Supreme DES (n = 645) versus DP-EES (n = 310). Patients with ACS were younger, fewer presented with less diabetes, hypertension, and previous revascularization, but more were current smokers. The primary end point of TLF (6.4% vs 4.4%; P = .1), major adverse cardiac events (8.5% vs 6.5%; P = .16), and stent thrombosis (0.4% vs 0.9%; P = .25) at 12 months were similar in the ACS and CCS groups. There was no difference in TLF at 12 months between Supreme DES and DP-EES among patients with ACS (6.6% vs 6.0%; P = .89) and those with CCS (4.5% vs 4.3%; P = .83); interaction P = .51 for TLF by clinical presentation.Conclusions
Compared with the DP-EES, the Supreme DES seemed safe and effective with a similar TLF at 12 months in both patients with ACS and those with CCS.
Date of Publication
2023
Publication Type
Article
Keyword(s)
acute coronary syndromes
•
biodegradable polymer drug-eluting stent
•
chronic coronary syndromes
•
durable polymer drug-eluting stents
•
endothelium
•
re-endothelialization
Language(s)
en
Contributor(s)
Hussain, Yasin
Saito, Shigeru
Curtis, Michael
Kereiakes, Dean J
Baumbach, Andreas
Zidar, James P
McLaurin, Brent
Dib, Nabil
Smits, Pieter C
Jiménez Díaz, Victor Alfonso
Cequier, Ángel
Hofma, Sjoerd H
Pietras, Cody
Dressler, Ovidiu
Issever, M Ozgu
Windecker, Stephan
Clinic of Cardiology
Leon, Martin B
Lansky, Alexandra J
Additional Credits
Clinic of Cardiology
Series
Journal of the Society for Cardiovascular Angiography & Interventions
Publisher
Elsevier
ISSN
2772-9303
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo