• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Effect of Additional Aluminum Filtration on the Image Quality in Cone Beam Computed Tomographic Studies of Equine Distal Limbs Using Visual Grading Characteristics Analysis: A Pilot Study.
 

Effect of Additional Aluminum Filtration on the Image Quality in Cone Beam Computed Tomographic Studies of Equine Distal Limbs Using Visual Grading Characteristics Analysis: A Pilot Study.

Options
  • Details
  • Files
BORIS DOI
10.48620/92903
Publisher DOI
10.3390/vetsci12111051
PubMed ID
41295689
Description
(1) Background: Cone beam computed tomography (CBCT) is increasingly used in equine practice to diagnose musculoskeletal injuries, including fractures in the distal limb. However, limited detail in the thick cortical bone of the metacarpus/metatarsus hinders accurate diagnosis. In human medicine, the addition of aluminum filters (AF) enhanced image quality while reducing radiation exposure. This study aimed to evaluate the effect of AF on image quality in CBCT scans of equine distal limbs. (2) Methods: Adult equine cadaver limbs were scanned with a mobile CBCT unit using varying tube currents (10-100 mA) and AF (13-25 mm). Two independent experts assessed the image quality using a four-point visual grading scale, focusing on cortical bone detail and artifacts. (3) Results: Higher tube currents generally improved image quality, but no filter was beneficial for the metacarpal/metatarsal regions. For the proximal phalanx, thicker AF (19-25 mm) improved image quality without significantly increasing the required tube current. (4) Conclusions: The optimal balance between image quality and radiation exposure using the O-arm® CBCT system for equine distal limbs was a tube current of 50 or 64 mA without filtration for the metacarpus/metatarsus, while a tube current of 50 mA with a 19-25 mm AF provided the best image quality for the proximal phalanx.
Date of Publication
2025-11-02
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
500 Science > 590 Animals (Zoology)
600 Technology > 630 Agriculture
Keyword(s)
diagnostic image quality assurance
•
filter
•
fissure
•
horse
•
tube current
Language(s)
en
Contributor(s)
Papini, Luca
Department of Clinical Veterinary Medicine
ISME Equine Clinic Bern
de Preux, Mathieu
ISME Equine Clinic Bern, Surgery
ISME Equine Clinic Bern & Avenches
ISME Universität Bern
Department of Clinical Veterinary Medicine
Pauwels, Frederik
Missotten, Joris
Department of Clinical Veterinary Medicine, Management
Van der Vekens, Elke
Department of Clinical Veterinary Medicine, Clinical Radiology
Additional Credits
ISME Universität Bern
ISME Equine Clinic Bern & Avenches
Department of Clinical Veterinary Medicine
ISME Equine Clinic Bern, Surgery
Department of Clinical Veterinary Medicine, Management
Department of Clinical Veterinary Medicine, Clinical Radiology
Series
Veterinary Sciences
Publisher
MDPI
ISSN
2306-7381
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo