• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Assessing XEN microstent's one-year efficacy: independent of site variability.
 

Assessing XEN microstent's one-year efficacy: independent of site variability.

Options
  • Details
  • Files
BORIS DOI
10.48620/85162
Publisher DOI
10.18240/ijo.2025.01.10
PubMed ID
39829609
Description
Aim
To evaluate the short-term efficacy of XEN45 Gel Stent (XEN) implantation for primary open angle glaucoma (POAG) and pseudoexfoliation (PEX) glaucoma across two university eye clinics, aiming to assess the impact of varying center-specific protocols during the first postoperative year.Methods
We retrospectively examined 282 patients (183 in center 1, 99 in center 2), who underwent XEN microstent implantation for uncontrolled POAG or PEX glaucoma. Parameters including intraocular pressure (IOP), IOP-lowering medication count, best corrected visual acuity (BCVA), and postoperative complications were evaluated over 12mo.Results
Post-implantation, center 1 reported a mean IOP reduction from 25.3±7.4 to 14.1±4.7 mm Hg (P<0.01) and a decrease in IOP-lowering medications from 3.2±1.2 to 1.0±1.3 (P<0.01). Center 2 observed a similar reduction from 24.4±6.5 to 15.1±5.5 mm Hg (P<0.01) and medication decrease from 3.0±1.1 to 1.2±1.0 (P<0.01). BCVA remained stable in both cohorts. The most common complications were hypotony (center 1: 32; center 2: 20) and choroidal detachment (center 1: 22, center 2: 15), with nearly identical needling rates (40% in center 1, 41% in center 2).Conclusion
XEN implantation yields consistent reductions in IOP and medication use across different centers using comparable surgical and postoperative treatment regime. These findings underscore XEN's short-term effectiveness and suggest standardizable outcomes regardless of exact surgical procedure or treatment differences.
Date of Publication
2025
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
XEN45 Gel Stent
•
glaucoma
•
minimally invasive glaucoma surgery
Language(s)
en
Contributor(s)
Bormann, Caroline
Busch, Catharina
Rehak, Matus
Scharenberg, Christian Thomas
Ziemssen, Focke
Unterlauft, Jan Darius
Clinic of Ophthalmology
Additional Credits
Clinic of Ophthalmology
Series
International journal of ophthalmology
Publisher
Press of International Journal of Ophthalmology
ISSN
2222-3959
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo