• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. An alternative radiation-free method for assessing the accuracy of robotic computer-assisted implant surgery: a cross-sectional study.
 

An alternative radiation-free method for assessing the accuracy of robotic computer-assisted implant surgery: a cross-sectional study.

Options
  • Details
  • Files
BORIS DOI
10.48620/94283
Publisher DOI
10.1016/j.jdent.2026.106523
PubMed ID
41581748
Description
Objectives
This study aimed to assess the accuracy of implant placement performed using robotic computer-assisted implant surgery (r-CAIS) by comparing postoperative measurements obtained via intraoral scanning (IOS) with those derived from cone-beam computed tomography (CBCT).Methods
The study employed a cross-sectional design. All patients received a preoperative CBCT and IOS for surgical planning and registration. All the surgeries were performed using r-CAIS. Postoperative CBCT and IOS datasets were acquired for each patient and superimposed on the preoperative datasets to assess deviations between planned and actual implant positions. Paired t-tests were used to analyze differences between the two assessment modalities, with statistical significance defined as P < 0.05. Agreement between the two methods was evaluated using intra-class correlation coefficients (ICCs) and Bland-Altman analyses.Results
Thirty-four implants in twenty-seven patients were included. Global coronal, global apical, and angular deviations measured using the IOS method were 0.59 ± 0.23 mm, 0.66 ± 0.24 mm, and 1.28 ± 0.69°, respectively, compared with 0.59 ± 0.24 mm, 0.63 ± 0.25 mm, and 1.19 ± 0.70° measured by the CBCT method. No statistically significant differences were observed between the two modalities (P > 0.05, respectively). ICCs for global coronal, global apical, and angular deviations were 0.911, 0.886, and 0.856, respectively. Bland-Altman analyses further confirmed excellent agreement between the two methods.Conclusions
Both IOS and CBCT methods demonstrated comparable accuracy and good agreement in r-CAIS.Clinical Significance
Postoperative IOS method may serve as a reliable and radiation-free alternative to CBCT for assessing implant placement accuracy in r-CAIS in patients with a single missing tooth or two consecutive missing teeth. In future, multicenter randomized controlled trials with larger sample sizes are warranted to further validate these findings.
Date of Publication
2026-04
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Accuracy
•
Cone beam computed tomography
•
Intraoral scan
•
Robotic computer-assisted implant surgery
Language(s)
en
Contributor(s)
Zhu, Rongrong
He, Longlong
Zhou, Qin
Zhang, Meng
Chang, Xiaofeng
Zhao, Ningbo
School of Dental Medicine, Clinic of Oral Surgery and Stomatology
Additional Credits
School of Dental Medicine, Clinic of Oral Surgery and Stomatology
Series
Journal of Dentistry
Publisher
Elsevier
ISSN
1879-176X
0300-5712
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo