• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Pulp sensitivity changes during orthodontic treatment at different time periods: a prospective study
 

Pulp sensitivity changes during orthodontic treatment at different time periods: a prospective study

Options
  • Details
  • Files
BORIS DOI
10.48350/164012
Publisher DOI
10.1007/s00784-020-03651-4
PubMed ID
33289047
Description
Objective The purpose of this investigation was to recognize pulp sensitivity changes in teeth receiving orthodontic treatment by means of an electric pulp tester (Vitality Scanner Model 2006; Kerr Corporation, Brea CA, USA).
Materials and methods An electric stimulus response threshold of eight teeth in 22 patients was measured prior to positioning orthodontic attachments, immediately before ligation of a nickel titanium archwire, immediately after ligation of a stainless steel archwire and 9 to 15 months after having achieved the clinical purposes established with the nickel titanium archwires. The first measurement served as baseline.
Results All teeth responded to an electrical stimulus at all times. No statistical differences were observed between the response thresholds obtained at different treatment times. The mean response threshold of the second measurement showed a decreasing response threshold tendency when compared with those of the baseline measurement. The mean response threshold of the third measurement showed an increasing tendency when compared with those of the baseline measurement. The first maxillary incisor and canine showed the lowest decreasing response threshold after the second measurement and the highest increasing response threshold after the third measurement. Less noticeable, but similar decreasing and increasing response threshold tendencies were observed in all other teeth after the second and third measurements, respectively.
Conclusions The results obtained in this investigation suggest that pulp sensitivity can be monitored during orthodontic treatment by means of an electric pulp tester.
Clinical relevance The importance of monitoring the pulp status during orthodontic treatment.
Date of Publication
2021-12-07
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Electric pulp tester
•
Pulp sensitivity
•
Orthodontic treatment
•
Orthodontic forces
Language(s)
en
Contributor(s)
Briseño Marroquin, Benjamin
Zahnmedizinische Kliniken, Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
Lopez-Murillo, Hector
Kuchen, Robert
Casasa-Araujo, Adan
Wolf, Thomas Gerhardorcid-logo
Zahnmedizinische Kliniken, Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
Additional Credits
Zahnmedizinische Kliniken, Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
Series
Clinical oral investigations
Publisher
Springer-Verlag
ISSN
1432-6981
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo