• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Estimation of Systolic and Diastolic Left Ventricular Blood Flow From Derivatives of Transesophageal Echocardiographic 3D Volume Curves in Cardiac Surgery Patients: A Proof-of-Concept Study.
 

Estimation of Systolic and Diastolic Left Ventricular Blood Flow From Derivatives of Transesophageal Echocardiographic 3D Volume Curves in Cardiac Surgery Patients: A Proof-of-Concept Study.

Options
  • Details
Publisher DOI
10.1177/10892532241286663
PubMed ID
39305511
Description
Objectives
To examine whether estimates of peak global systolic (S') and diastolic (E') left ventricular (LV) flow rates based on 3D echocardiographic volumes are feasible and match physiology.Methods
In this retrospective feasibility study, we included patients undergoing major cardiac surgery. S' and E' were derived from 190 patients by taking the first derivative of the volume-time relationship of 3D ecg-gated transesophageal echocardiography (TEE) images. To examine the quality of images upon which the estimates of flow were based we correlated intraoperative 3D TEE and preoperative 2D transthoracic echocardiography (TTE) volumes. As a proof-of-concept, we then correlated S' flow with stroke volume and S' and E' were compared by valve pathology.Results
In each of the 190 images, S' and E' were derived. There was good correlation between 1) the ejection fraction (EF) of 3D LV images obtained intraoperatively by TEE and preoperatively by TTE (Pearson's r = 0.65) and also 2) S' and stroke volume (Pearson's r = 0.73). Patients with aortic or mitral regurgitation showed higher S' than patients without valve pathologies (-315 mL/s [95% CI -388 mL/s to -264 mL/s] = 0.001, -319 mL/s [95% CI -397 mL/s to -246 mL/s] = 0.001 vs -242 mL/s [95% CI -300 mL/s to -196 mL/s]). These patients also showed higher E' than patients without valve pathologies (302 mL/s [95% CI 237 mL/s to 384 mL/s] = 0.006, 341 mL/s [95%CI 227 mL/s to 442 mL/s] = 0.001 vs 240 mL/s [95%CI 185 mL/s to 315 mL/s]). Patients with aortic stenosis showed no difference in S' or E' (-263 mL/s [95%CI -300 mL/s to -212 mL/s] = 0.793, 255 mL/s [95%CI 188 mL/s to 344 mL/s] = 0.400).Conclusions
Estimates of global peak systolic and diastolic LV flow based on 3D TEE are feasible, promising, and match valve pathologies.
Date of Publication
2024-12
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
3D echocardiography
•
cardiac output
•
echocardiography
•
left ventricular function
•
speckle-tracking
•
valve pathology
Language(s)
en
Contributor(s)
Jokiel, Paul-Michael
Schweizer, Thilo
Clinic and Policlinic for Anaesthesiology and Pain Therapy
Guensch, Dominik Porcid-logo
Clinic and Policlinic for Anaesthesiology and Pain Therapy
Clinic and Policlinic for Anaesthesiology and Pain Therapy
Berdajs, Denis
Erb, Joachim
Bolliger, Daniel
Kamber, Firmin
Mauermann, Eckhard
Additional Credits
Clinic and Policlinic for Anaesthesiology and Pain Therapy
Clinic and Policlinic for Anaesthesiology and Pain Therapy
Series
Seminars in Cardiothoracic and Vascular Anesthesia
Publisher
SAGE Publications
ISSN
1089-2532
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo