  3. Evaluation of N-acetyltaurine as an ethanol marker in human blood.
 

Evaluation of N-acetyltaurine as an ethanol marker in human blood.

Options
  • Details
Publisher DOI
10.1016/j.alcohol.2017.05.007
PubMed ID
29084624
Description
To investigate the potential of N-acetyltaurine (NAcT) in blood as a biomarker for alcohol uptake, a previously published LC-MS/MS method for urine was modified to simultaneously detect NAcT and ethyl glucuronide (EtG). The method was applied in a drinking study and by analyzing 147 forensic case samples. In the drinking study, contrary to EtG, NAcT proved to be an endogenous substance, which was present at 22 ± 7 ng/mL (13-31 ng/mL) in the blood after 2 weeks of abstinence. A moderate increase in NAcT to 40 ± 10 ng/mL (27-57 ng/mL) was observed after drinking. Within 24 h, the NAcT concentrations declined to starting concentrations in seven out of eight subjects. Peak EtG concentrations (c¯max) of 445 ± 101 ng/mL (278-662 ng/mL) were reached. While EtG in blood can be used to detect alcohol consumption even if ethanol is already eliminated, some of the maximum NAcT concentrations after a single ethanol dose were in the range of endogenous levels detected prior to the start of drinking in other subjects. In the 147 blood samples, the following concentrations were found: blood alcohol concentration (BAC): 1.22 ± 0.95 g/kg (0-3.46 g/kg); NAcT: 37.8 ± 18.4 ng/mL (12.1-109 ng/mL); EtG: 1149 ± 1121 ng/mL (0-5950 ng/mL). ROC curve analysis for BAC thresholds at 0.8 and 1.6 g/kg were performed for EtG and NAcT. Due to the presence of endogenous NAcT levels resulting in a lower sensitivity and selectivity when compared to EtG, and due to a minor increase in concentration after alcohol uptake, the usefulness of NAcT as an alcohol biomarker in blood is very limited.
Date of Publication
2017-12
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
500 Science > 570 Life sciences; biology
500 Science > 540 Chemistry
Keyword(s)
Alcohol abstinence monitoring Blood alcohol Direct alcohol marker Ethyl glucuronide LC–MS/MS N-acetyltaurine
Language(s)
en
Contributor(s)
Luginbühl, Marc Joel
Institut für Rechtsmedizin, Forensische Chemie und Toxikologie
Institut für Rechtsmedizin (IRM)
König, Stefan
Institut für Rechtsmedizin (IRM)
Institut für Rechtsmedizin, Forensische Chemie und Toxikologie
Schürch, Stefan
Departement für Chemie und Biochemie (DCB)
Weinmann, Wolfgang
Institut für Rechtsmedizin, Forensische Chemie und Toxikologie
Institut für Rechtsmedizin (IRM)
Institut für Rechtsmedizin, Direktion
Additional Credits
Institut für Rechtsmedizin, Forensische Chemie und Toxikologie
Institut für Rechtsmedizin (IRM)
Departement für Chemie und Biochemie (DCB)
Series
Alcohol
Publisher
Elsevier
ISSN
0741-8329
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo