Publication:
Navigated intraoperative analysis of lower limb alignment

cris.virtual.author-orcid0000-0003-4173-0379
cris.virtualsource.author-orcid99920203-d10f-4dc4-b267-880e3c567ccd
cris.virtualsource.author-orcidcf7f7cd6-9787-41e1-a3be-273d48cce324
cris.virtualsource.author-orcid010c8b4e-414f-47da-b81e-c71cf5709a0b
datacite.rightsopen.access
dc.contributor.authorHankemeier, Stefan
dc.contributor.authorHufner, Tobias
dc.contributor.authorWang, Gongli
dc.contributor.authorKendoff, Daniel
dc.contributor.authorZheng, Guoyan
dc.contributor.authorRichter, Martinus
dc.contributor.authorGosling, Thomas
dc.contributor.authorNolte, Lutz-Peter
dc.contributor.authorKrettek, Christian
dc.date.accessioned2024-10-24T17:22:58Z
dc.date.available2024-10-24T17:22:58Z
dc.date.issued2005
dc.description.abstractINTRODUCTION: Accurate intraoperative assessment of lower limb alignment is crucial for the treatment of long bone fractures, implantation of knee arthroplasties and correction of deformities. During orthopaedic surgery, exact real time control of the mechanical axis is strongly desirable. The aim of this study was to compare conventional intraoperative analysis of the mechanical axis by the cable method with continuous, 3-dimensional imaging with a navigation system. MATERIALS AND METHODS: Twenty legs of fresh human cadaver were randomly assigned to conventional analysis with the cable method (n = 10) or navigated analysis with a fluoroscopy based navigation system (n = 10). The intersection of the mechanical axis with the tibia plateau was presented as percentage of the tibia plateau (beginning with 0% at the medial border and ending with 100% laterally). CT-scans were performed for all legs and the CT-values of the mechanical axis were compared to the measurements after cable method and navigation. Furthermore, the radiation time and dose area product of both groups for single analysis of the mechanical axis was compared. RESULTS: Conventional evaluation of the mechanical axis by the cable method showed 6.0+/-3.1% difference compared to the analysis by CT. In the navigated group the difference was 2.6+/-1.8% (P = 0.008). Radiation time and dose area product were highly significantly lower after conventional measurement. CONCLUSIONS: Navigated intraoperative evaluation of the mechanical axis offers increased accuracy compared to conventional intraoperative analysis. Furthermore, navigation provides continuous control not only of the mechanical axis, but also of the sagittal and transverse plane. Using the cable method, radiation exposure depends on the number of measurements and is lower compared to the navigation system for single intraoperative analysis of the mechanical axis, but may be higher in case of repeated intraoperative measurements.
dc.description.numberOfPages5
dc.description.sponsorshipInstitut für chirurgische Technologien und Biomechanik (ISTB)
dc.identifier.doi10.48350/82206
dc.identifier.pmid16096798
dc.identifier.publisherDOI10.1007/s00402-005-0038-9
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/142047
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofArchives of orthopaedic and trauma surgery
dc.relation.issn0936-8051
dc.relation.organizationInstitute for Surgical Technology and Biomechanics (ISTB)
dc.subject.ddc500 - Science::570 - Life sciences; biology
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleNavigated intraoperative analysis of lower limb alignment
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage535
oaire.citation.issue8
oaire.citation.startPage531
oaire.citation.volume125
oairecerif.author.affiliationInstitut für chirurgische Technologien und Biomechanik (ISTB)
oairecerif.author.affiliationInstitut für chirurgische Technologien und Biomechanik (ISTB)
oairecerif.author.affiliationInstitut für chirurgische Technologien und Biomechanik (ISTB)
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2022-04-28 13:10:48
unibe.description.ispublishedpub
unibe.eprints.legacyId82206
unibe.journal.abbrevTitleARCH ORTHOP TRAUM SU
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
Hankemeier2005_Article_NavigatedIntraoperativeAnalysi.pdf
Size:
281.88 KB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published

Collections