Publication:
Computer planned, image-guided combined resection and ablation for bilobar colorectal liver metastases

cris.virtualsource.author-orcid5cf54cef-0b9b-48ee-a517-51eafd1fb458
cris.virtualsource.author-orcidb5363e32-8d26-4e41-963d-b0d8876766ed
cris.virtualsource.author-orcid8830089c-b489-4354-849f-83088e3eaba2
cris.virtualsource.author-orcidc479ce0f-a113-4d12-bdae-be1151da1802
cris.virtualsource.author-orcidecebc32d-f210-4b1e-a3a7-dd9cc3c7d198
cris.virtualsource.author-orcidced8ad6c-6df4-4abe-b8e3-bab8411c5def
datacite.rightsopen.access
dc.contributor.authorBanz Wüthrich, Vanessa
dc.contributor.authorBächtold, Matthias Alexander
dc.contributor.authorWeber, Stefan
dc.contributor.authorPeterhans, Matthias
dc.contributor.authorInderbitzin, Daniel
dc.contributor.authorCandinas, Daniel
dc.date.accessioned2024-10-23T17:56:31Z
dc.date.available2024-10-23T17:56:31Z
dc.date.issued2014
dc.description.abstractFor patients with extensive bilobar colorectal liver metastases (CRLM), initial surgery may not be feasible and a multimodal approach including microwave ablation (MWA) provides the only chance for prolonged survival. Intraoperative navigation systems may improve the accuracy of ablation and surgical resection of so-called "vanishing lesions", ultimately improving patient outcome. Clinical application of intraoperative navigated liver surgery is illustrated in a patient undergoing combined resection/MWA for multiple, synchronous, bilobar CRLM. Regular follow-up with computed tomography (CT) allowed for temporal development of the ablation zones. Of the ten lesions detected in a preoperative CT scan, the largest lesion was resected and the others were ablated using an intraoperative navigation system. Twelve months post-surgery a new lesion (Seg IVa) was detected and treated by trans-arterial embolization. Nineteen months post-surgery new liver and lung metastases were detected and a palliative chemotherapy started. The patient passed away four years after initial diagnosis. For patients with extensive CRLM not treatable by standard surgery, navigated MWA/resection may provide excellent tumor control, improving longer-term survival. Intraoperative navigation systems provide precise, real-time information to the surgeon, aiding the decision-making process and substantially improving the accuracy of both ablation and resection. Regular follow-ups including 3D modeling allow for early discrimination between ablation zones and recurrent tumor lesions.
dc.description.numberOfPages5
dc.description.sponsorshipUniversitätsklinik für Viszerale Chirurgie und Medizin
dc.description.sponsorshipARTORG Center - Image Guided Therapy
dc.description.sponsorshipARTORG Center for Biomedical Engineering Research
dc.description.sponsorshipUniversitätsklinik für Viszerale Chirurgie und Medizin, Viszeral- und Transplantationschirurgie
dc.identifier.doi10.7892/boris.65337
dc.identifier.pmid25356061
dc.identifier.publisherDOI10.3748/wjg.v20.i40.14992
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/130866
dc.language.isoen
dc.publisherWJG Press
dc.relation.ispartofWorld journal of gastroenterology
dc.relation.issn1007-9327
dc.relation.organizationClinic of Visceral Surgery and Medicine, Visceral and Transplant Surgery
dc.relation.organizationARTORG Center for Biomedical Engineering Research
dc.relation.organizationARTORG Center - Image Guided Therapy (IGT)
dc.relation.organizationClinic of Visceral Surgery and Medicine
dc.relation.schoolGraduate School for Cellular and Biomedical Sciences (GCB)
dc.subjectColorectal liver metastases
dc.subjectComputer navigation
dc.subjectImage-guidance
dc.subjectMicrowave ablation
dc.subjectTumor
dc.subject.ddc500 - Science::570 - Life sciences; biology
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleComputer planned, image-guided combined resection and ablation for bilobar colorectal liver metastases
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage14996
oaire.citation.issue40
oaire.citation.startPage14992
oaire.citation.volume20
oairecerif.author.affiliationUniversitätsklinik für Viszerale Chirurgie und Medizin, Viszeral- und Transplantationschirurgie
oairecerif.author.affiliationUniversitätsklinik für Viszerale Chirurgie und Medizin
oairecerif.author.affiliationARTORG Center - Image Guided Therapy
oairecerif.author.affiliationARTORG Center for Biomedical Engineering Research
oairecerif.author.affiliationUniversitätsklinik für Viszerale Chirurgie und Medizin, Viszeral- und Transplantationschirurgie
oairecerif.author.affiliationUniversitätsklinik für Viszerale Chirurgie und Medizin, Viszeral- und Transplantationschirurgie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.description.ispublishedpub
unibe.eprints.legacyId65337
unibe.journal.abbrevTitleWORLD J GASTROENTERO
unibe.refereedtrue
unibe.subtype.articlecontribution

Files

Original bundle
Now showing 1 - 1 of 1
Name:
WJG-Computer planned, image-guided.pdf
Size:
1.04 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by-nc-nd/4.0
Content:
published

Collections