• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Effect of length of LOCATOR abutment and cement type on retention to intraradicular dentin in overdentures.
 

Effect of length of LOCATOR abutment and cement type on retention to intraradicular dentin in overdentures.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.134340
Publisher DOI
10.1016/j.prosdent.2019.04.023
PubMed ID
31326148
Description
STATEMENT OF PROBLEM

Limited information is available on the effect of LOCATOR abutment length and luting cement type on retention to intraradicular dentin in overdentures.

PURPOSE

The purpose of this in vitro study was to evaluate the effect of the length of a commercially available LOCATOR abutment and cement type on retention in the root canal.

MATERIAL AND METHODS

Eighty LOCATOR abutments with a standard length of 6 mm were obtained. Half of them were shortened to 3 mm. Eighty recently extracted single-rooted teeth were divided into 2 groups. The post space was prepared to 6 mm in the first group and 3 mm in the second. After preparation, the LOCATOR abutments were luted with one of the following cements: dual-polymerized glass-reinforced resin cement (Parapost Paracore), dual-polymerized resin cement (Variolink II), self-adhesive resin cement (RelyX Unicem), and conventional cement (zinc phosphate). The tensile force required for the removal of the LOCATOR abutments from their corresponding roots was recorded. Data were statistically analyzed with 2-way ANOVA and the Tukey multiple comparison test.

RESULTS

Both the cement type (P<.001) and the length of the LOCATOR abutment (P<.001) significantly affected the mean tensile forces. Dual-polymerized glass-reinforced resin cement (Parapost Paracore) presented significantly higher mean tensile forces for the LOCATOR abutment retention among all cements (P<.05).

CONCLUSIONS

Regardless of the length, LOCATOR abutments luted with Parapost Paracore resin cement presented higher mean resistance to tensile forces compared with those luted with the other cements. LOCATOR abutments of 6 mm in length were more resistant to tensile forces than those of 3 mm in length in combination with all cements.
Date of Publication
2019-08
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Aleisa, Khalil
Al-Dwairi, Ziad
Abou-Obaid, Alaa
Al-Muharib, Aseel
Al-Rejaye, Najla
Morgano, Steven M
Al-Haj Husain, Nadin
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Özcan, Mutlu
Additional Credits
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Series
The journal of prosthetic dentistry
Publisher
Elsevier
ISSN
1097-6841
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo