• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Flexural strength and Weibull characteristics of stereolithography additive manufactured versus milled zirconia.
 

Flexural strength and Weibull characteristics of stereolithography additive manufactured versus milled zirconia.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.146286
Publisher DOI
10.1016/j.prosdent.2020.01.019
PubMed ID
32434662
Description
STATEMENT OF PROBLEM

Zirconia restorations can be processed by using stereolithography additive manufacturing (AM) technologies. However, whether additive manufactured zirconia could achieve flexural strength values comparable with those of milled zirconia is unclear.

PURPOSE

The purpose of this in vitro study was to compare the flexural strength and Weibull characteristics of milled and additive manufactured zirconia.

MATERIAL AND METHODS

A total of 40 zirconia bars (25×4×1.2 mm) were obtained by using 2 manufacturing procedures, subtractive (CNC group) (IPS e.max ZirCAD; Ivoclar Vivadent AG) and additive manufacturing (AM group) (3DMix ZrO2; 3DCeram) technologies and assigned to 2 subgroups according to accelerating artificial aging procedures (mastication simulation): nonaged and aged (n=10). Flexural strength was measured in all specimens by using 3-point bend tests according to ISO/CD 6872.2 with a universal testing machine (Instron Model 8501; Instron Corp). Two-parameter Weibull distribution values, including the Weibull modulus, scale (m), and shape (0) were calculated. Flexural strength values were analyzed by using 2-way ANOVA and Student t statistical tests (α=.05).

RESULTS

The manufacturing procedure (P<.001), the mastication simulating aging procedure (P<.001), and the interaction between them (P<.001) significantly affected flexural strength values. The CNC group exhibited statistically higher flexural strength values than those in the AM group when the specimens were tested before performing an aging procedure (P<.001) and after mastication simulation (P<.001). Moreover, mastication simulation produced a significant reduction in flexural strength for both the CNC group (P<.039) and the AM group (P<.001).

CONCLUSIONS

The manufacturing process reported a significant effect on the flexural strength of the zirconia material tested. Mastication simulation as a means of accelerating artificial aging resulted in the significantly decreased flexural strength values of milled and additively manufactured zirconia material, with the Weibull moduli being significantly higher for the milled groups versus the milled specimens.
Date of Publication
2021-04
Publication Type
Article
Subject(s)
600 Technology
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Revilla-León, Marta
Al-Haj Husain, Nadin
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Ceballos, Laura
Özcan, Mutlu
Additional Credits
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Series
The journal of prosthetic dentistry
Publisher
Elsevier
ISSN
1097-6841
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo