Publication:
Imaging of Bioprosthetic Valve Dysfunction after Transcatheter Aortic Valve Implantation.

cris.virtual.author-orcid0000-0003-3149-2944
cris.virtualsource.author-orcid859fc71f-01b2-4eeb-afc9-4ec70bc32591
cris.virtualsource.author-orcid47930625-0932-433e-a748-62a9304dfed4
cris.virtualsource.author-orcida1b35a2a-1102-4388-a033-835d30602e58
cris.virtualsource.author-orcidc817885a-7b7d-4187-8412-66d624885a26
cris.virtualsource.author-orcide58d604d-1e1c-4387-94ae-cf69dd2a3ea3
cris.virtualsource.author-orcid101f1394-72d5-4dda-b28f-666a3dee6c70
cris.virtualsource.author-orcidb7cda86d-8924-42a5-973a-d73fee5c630b
cris.virtualsource.author-orcid51373a0c-6282-4884-bb5e-09ddec6eebd6
datacite.rightsopen.access
dc.contributor.authorAlwan, Louhai
dc.contributor.authorBernhard, Benedikt
dc.contributor.authorBrugger, Nicolas Jacques
dc.contributor.authorDe Marchi, Stefano
dc.contributor.authorPraz, Fabien Daniel
dc.contributor.authorWindecker, Stephan
dc.contributor.authorPilgrim, Thomas
dc.contributor.authorGräni, Christoph
dc.date.accessioned2024-10-25T16:40:10Z
dc.date.available2024-10-25T16:40:10Z
dc.date.issued2023-05-29
dc.description.abstractTranscatheter aortic valve implantation (TAVI) has become the standard of care in elderly high-risk patients with symptomatic severe aortic stenosis. Recently, TAVI has been increasingly performed in younger-, intermediate- and lower-risk populations, which underlines the need to investigate the long-term durability of bioprosthetic aortic valves. However, diagnosing bioprosthetic valve dysfunction after TAVI is challenging and only limited evidence-based criteria exist to guide therapy. Bioprosthetic valve dysfunction encompasses structural valve deterioration (SVD) resulting from degenerative changes in the valve structure and function, non-SVD resulting from intrinsic paravalvular regurgitation or patient-prosthesis mismatch, valve thrombosis, and infective endocarditis. Overlapping phenotypes, confluent pathologies, and their shared end-stage bioprosthetic valve failure complicate the differentiation of these entities. In this review, we focus on the contemporary and future roles, advantages, and limitations of imaging modalities such as echocardiography, cardiac computed tomography angiography, cardiac magnetic resonance imaging, and positron emission tomography to monitor the integrity of transcatheter heart valves.
dc.description.numberOfPages19
dc.description.sponsorshipUniversitätsklinik für Kardiologie
dc.identifier.doi10.48350/183311
dc.identifier.pmid37296760
dc.identifier.publisherDOI10.3390/diagnostics13111908
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/167750
dc.language.isoen
dc.publisherMDPI
dc.relation.ispartofDiagnostics
dc.relation.issn2075-4418
dc.relation.organizationDCD5A442BB15E17DE0405C82790C4DE2
dc.subjectTAVI bioprosthetic valve dysfunction bioprosthetic valve failure multimodality imaging structural valve deterioration
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleImaging of Bioprosthetic Valve Dysfunction after Transcatheter Aortic Valve Implantation.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.issue11
oaire.citation.volume13
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2023-06-12 09:30:49
unibe.description.ispublishedpub
unibe.eprints.legacyId183311
unibe.refereedtrue
unibe.subtype.articlereview

Files

Original bundle
Now showing 1 - 1 of 1
Name:
diagnostics-13-01908-v2.pdf
Size:
2.04 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by/4.0
Content:
published

Collections