• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Validation of a new method for determination of cup orientation in THA
 

Validation of a new method for determination of cup orientation in THA

Options
  • Details
Publisher DOI
10.1002/jor.20929
PubMed ID
19544389
Description
Our goal was to validate accuracy, consistency, and reproducibility/reliability of a new method for determining cup orientation in total hip arthroplasty (THA). This method allows matching the 3D-model from CT images or slices with the projected pelvis on an anteroposterior pelvic radiograph using a fully automated registration procedure. Cup orientation (inclination and anteversion) is calculated relative to the anterior pelvic plane, corrected for individual malposition of the pelvis during radiograph acquisition. Measurements on blinded and randomized radiographs of 80 cadaver and 327 patient hips were investigated. The method showed a mean accuracy of 0.7 +/- 1.7 degrees (-3.7 degrees to 4.0 degrees) for inclination and 1.2 +/- 2.4 degrees (-5.3 degrees to 5.6 degrees) for anteversion in the cadaver trials and 1.7 +/- 1.7 degrees (-4.6 degrees to 5.5 degrees) for inclination and 0.9 +/- 2.8 degrees (-5.2 degrees to 5.7 degrees) for anteversion in the clinical data when compared to CT-based measurements. No systematic errors in accuracy were detected with the Bland-Altman analysis. The software consistency and the reproducibility/reliability were very good. This software is an accurate, consistent, reliable, and reproducible method to measure cup orientation in THA using a sophisticated 2D/3D-matching technique. Its robust and accurate matching algorithm can be expanded to statistical models.
Date of Publication
2009
Publication Type
Article
Language(s)
en
Contributor(s)
Steppacher, Simon Damian
Universitätsklinik für Orthopädische Chirurgie
Tannast, Moritz
Universitätsklinik für Orthopädische Chirurgie
Zheng, Guoyanorcid-logo
Institut für chirurgische Technologien und Biomechanik (ISTB)
Zhang, X
Kowal, Horst Jens
Institut für chirurgische Technologien und Biomechanik (ISTB)
Anderson, SE
Siebenrock, Klaus-Arno
Universitätsklinik für Orthopädische Chirurgie
Murphy, SB
Additional Credits
Universitätsklinik für Orthopädische Chirurgie
Institut für chirurgische Technologien und Biomechanik (ISTB)
Series
Journal of orthopaedic research
Publisher
Wiley
ISSN
0736-0266
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo