Publication: Concentration and Chemical Stability of Commercially Available Insulins: A High-Resolution Mass Spectrometry Study.
cris.virtual.author-orcid | 0000-0002-6740-5980 | |
cris.virtualsource.author-orcid | e27483a2-c8d3-4694-ac0d-c5337f5771cf | |
cris.virtualsource.author-orcid | 4fd2f7c2-7be6-49bb-99cb-b03db2efc9b7 | |
cris.virtualsource.author-orcid | 09befecc-5486-4f86-937d-2f3bd875570b | |
cris.virtualsource.author-orcid | c2015e54-f96e-4908-93b7-36afcb30fd38 | |
datacite.rights | open.access | |
dc.contributor.author | Baechler, Fabio | |
dc.contributor.author | Stettler, Christoph | |
dc.contributor.author | Vogt, Bruno | |
dc.contributor.author | Bally, Lia Claudia | |
dc.contributor.author | Grössl, Michael | |
dc.date.accessioned | 2024-09-20T09:20:27Z | |
dc.date.available | 2024-09-20T09:20:27Z | |
dc.date.issued | 2020-02-07 | |
dc.description.abstract | Adequacy of insulin concentration in commercially available insulin formulations has recently been challenged. We therefore repeatedly evaluated insulin content and stability of 58 insulin vials containing 5 different insulin formulations (human insulin, standard/faster-acting insulin aspart, insulin lispro, and insulin glargine) over a period of 85 days. High-resolution mass spectrometry was used to quantify intact monomeric insulin in glass vials and plastic pump cartridges exposed to three different temperatures (4°C, 22°C, 37°C), simulating real-life conditions. In all cases, measured insulin concentration was in accordance with FDA and European Medicines Agency (EMA) requirements without evidence of chemical instability. | |
dc.description.numberOfPages | 4 | |
dc.description.sponsorship | Universitätsklinik für Nephrologie und Hypertonie | |
dc.description.sponsorship | Universitätsklinik für Diabetologie, Endokrinologie, Ernährungsmedizin & Metabolismus (UDEM) | |
dc.identifier.doi | 10.7892/boris.147857 | |
dc.identifier.pmid | 32031881 | |
dc.identifier.publisherDOI | 10.1089/dia.2019.0412 | |
dc.identifier.uri | https://boris-portal.unibe.ch/handle/20.500.12422/45098 | |
dc.language.iso | en | |
dc.publisher | Mary Ann Liebert | |
dc.relation.ispartof | Diabetes technology & therapeutics | |
dc.relation.issn | 1520-9156 | |
dc.relation.organization | DCD5A442C268E17DE0405C82790C4DE2 | |
dc.relation.organization | DCD5A442BB17E17DE0405C82790C4DE2 | |
dc.relation.organization | DCD5A442C012E17DE0405C82790C4DE2 | |
dc.subject | Analogs Insulin Mass spectrometry Quality assurance Therapeutic aspects | |
dc.subject.ddc | 600 - Technology::610 - Medicine & health | |
dc.title | Concentration and Chemical Stability of Commercially Available Insulins: A High-Resolution Mass Spectrometry Study. | |
dc.type | article | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 329 | |
oaire.citation.issue | 4 | |
oaire.citation.startPage | 326 | |
oaire.citation.volume | 22 | |
oairecerif.author.affiliation | Universitätsklinik für Diabetologie, Endokrinologie, Ernährungsmedizin & Metabolismus (UDEM) | |
oairecerif.author.affiliation | Universitätsklinik für Nephrologie und Hypertonie | |
oairecerif.author.affiliation | Universitätsklinik für Diabetologie, Endokrinologie, Ernährungsmedizin & Metabolismus (UDEM) | |
oairecerif.author.affiliation | Universitätsklinik für Nephrologie und Hypertonie | |
oairecerif.author.affiliation2 | Department for BioMedical Research, Forschungsgruppe Nephrologie / Hypertonie | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.date.embargoChanged | 2021-03-25 01:30:05 | |
unibe.date.licenseChanged | 2020-11-10 08:11:19 | |
unibe.description.ispublished | pub | |
unibe.eprints.legacyId | 147857 | |
unibe.journal.abbrevTitle | DIABETES TECHNOL THE | |
unibe.refereed | true | |
unibe.subtype.article | journal |