• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Projects
  • Research Data
  • Organizations
  • Researchers
  • Statistics
  • More
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. 99mTc-MAG3 Diuretic Renography: Intra- and Inter-Observer Repeatability in the Assessment of Renal Function.
 

99mTc-MAG3 Diuretic Renography: Intra- and Inter-Observer Repeatability in the Assessment of Renal Function.

Options
  • Details
  • Files
BORIS DOI
10.48350/149134
Publisher DOI
10.3390/diagnostics10090709
PubMed ID
32957695
Description
The aim of the present study is to evaluate the intra- and inter-observer agreement in assessing the renal function by means of 99mTc-MAG3 diuretic renography. One hundred and twenty adults were enrolled in the study. One experienced and one junior radiographer processed the renograms twice by assigning manual and semi-automated regions of interest. The differential renal function (DRF, %), time to maximum counts for the right and left kidney (TmaxR-TmaxL, min) and time to half-peak counts (T1/2, min) were calculated. The Bland-Altman analysis (bias±95% limits of agreement), Lin's concordance correlation coefficient and weighted Fleiss' kappa coefficient were used to assess agreement. Based on the Bland-Altman analysis, the intra-observer repeatability results for the experienced radiographer using the manual and the semi-automated techniques were 0.2 ± 2.6% and 0.3 ± 6.4% (DRF), respectively, -0.01 ± 0.24 and 0.00 ± 0.34 (TmaxR), respectively, and 0.00 ± 0.26 and 0.00 ± 0.33 (TmaxL), respectively. For the junior radiographer, the respective results were 0.5 ± 5.0% and 0.8 ± 9.4% (DRF), 0.00 ± 0.44 and 0.01 ± 0.28 (TmaxR), and 0.01 ± 0.28 and -0.02 ± 0.44 (TmaxL). The inter-observer repeatability for the manual method was 0.6 ± 5.0% (DRF), -0.10 ± 0.42 (TmaxR) and -0.05 ± 0.38 (TmaxL), and for the semi-automated method -0.2 ± 9.1% (DRF), 0.00 ± 0.31 (TmaxR) and -0.05 ± 0.40 (TmaxL). The weighted Fleiss' kappa coefficient for the T1/2 assessments ranged between 0.85-0.97 for both intra- and inter-observer repeatability with both methods. These findings suggest a very good repeatability in DRF assessment with the manual method-especially for the experienced observer-but a less good repeatability with the semi-automated approach. The calculation of Tmax was also operator-dependent. We conclude that reader experience is important in the calculation of renal parameters. We therefore encourage reader training in renal scintigraphy. Moreover, the manual tool seems to perform better than the semi-automated tool. Thus, we encourage cautious use of automated tools and adjunct validation by manual methods where possible.
Date of Publication
2020-09-17
Publication Type
Article
Subject(s)
600 - Technology::610 - Medicine & health
Keyword(s)
99mTc-MAG3 diuretic renography inter-observer intra-observer repeatability
Language(s)
en
Contributor(s)
Sachpekidis, Christos
Universitätsklinik für Nuklearmedizin
Schepers, Robin
Marti, Monika
Kopp-Schneider, Annette
Alberts, Ian Leigh
Universitätsklinik für Nuklearmedizin
Keramida, Georgia
Afshar Oromieh, Ali
Universitätsklinik für Nuklearmedizin
Rominger, Axel Oliverorcid-logo
Universitätsklinik für Nuklearmedizin
Additional Credits
Universitätsklinik für Nuklearmedizin
Series
Diagnostics
Publisher
MDPI
ISSN
2075-4418
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: ae9592 [15.12. 16:43]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo