Cementless hemiarthroplasty in femoral neck fractures: evaluation of clinical results and measurement of migration by EBRA-FCA
Options
BORIS DOI
Publisher DOI
PubMed ID
16557369
Description
Aim of the present study was to evaluate migration rates of cementless primary hemiarthroplasty in acute femoral neck fractures. In a longitudinal, prospective study 46 patients were treated by cementless hemiarthroplasty. Clinical follow up was correlated with the EBRA-FCA method. In 30% of all patients stem migration amounted to more than 2 mm; further, these patients were seen to have a high level of activity. A high degree of migration in more than 30% of all patients requires critical scepticism toward further use of the investigated cementless stem as hemiarthroplasty. According to literature, migration of more than 2 mm suggests a high probability of early aseptic loosening. In patients with a low degree of activity good results could be observed; nevertheless, in patients with a high level of activity the combination of the investigated cementless stem with a solid fracture head cannot be recommended.
Date of Publication
2006
Publication Type
Article
Language(s)
en
Contributor(s)
Klestil, T | |
Biedermann, R | |
Gföller, P | |
Schmoelz, W | |
Rangger, C | |
Krismer, M | |
Blauth, M |
Additional Credits
Series
Archives of orthopaedic and trauma surgery
Publisher
Springer
ISSN
0936-8051
ISBN
16557369
Access(Rights)
open.access