• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Marginal gap of printed, milled, and heat-pressed two-piece polyetheretherketone abutments before and after thermal cycling, and their pull-off bond strength after thermal cycling.

Marginal gap of printed, milled, and heat-pressed two-piece polyetheretherketone abutments before and after thermal cycling, and their pull-off bond strength after thermal cycling.

Details
Files
DOI
10.48620/87695
Publisher DOI
10.1111/jopr.14052
PubMed ID
40176355
Abstract
Purpose
To evaluate the marginal gap of two-piece polyetheretherketone (PEEK) abutments fabricated with different methods, before and after thermal cycling, while also focusing on their pull-off bond strength.
Materials And Methods
A two-piece abutment was virtually designed after digitizing a titanium-base (Ti-base) abutment. This design was used to fabricate printed (P-PEEK), milled (M-PEEK), and heat-pressed (HP-PEEK) PEEK abutments (n = 8). The marginal gaps of all abutments were evaluated under a stereomicroscope (15 points on each side, ×40 magnification), before and after thermal cycling (10,000 cycles, 5°C-55°C). Then, all abutments were subjected to a pull-off bond strength test. The marginal gap data were analyzed with a generalized linear model, while the pull-off bond strength data were analyzed with one-way analysis of variance and Tukey tests (α = 0.05).
Results
The marginal gaps were affected by the interaction between the fabrication method and aging condition, as well as by the fabrication method and aging condition (p ≤ 0.003). HP-PEEK abutments before thermal cycling had the lowest gap, whereas M-PEEK abutments after thermal cycling mostly had the highest (p ≤ 0.042). Thermal cycling increased the marginal gap of HP-PEEK (p < 0.001). M-PEEK had the lowest and HP-PEEK had the highest pull-off bond strength (p < 0.001). Most of the failures of P-PEEK and M-PEEK abutments were mixed.
Conclusions
The tested abutments had marginal gaps below the clinically acceptable threshold of 120 µm, both before and after thermal cycling. HP-PEEK abutments may be more resistant to dislodgment from the Ti-base abutments than P-PEEK and M-PEEK abutments.
Date Issued
2025-04-02
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Author(s)
Diken Türksayar, Almira Ada
Kanpalta, Burcu
Bulucu, Naime Bilinç
Schulnig, Sandra
Spintzyk, Sebastian
Demirel, Münir
Donmez, Mustafa Borga  
School of Dental Medicine  
School of Dental Medicine, Department of Reconstructive Dentistry and Gerodontology  
Additional Credits
School of Dental Medicine, Department of Reconstructive Dentistry and Gerodontology  
School of Dental Medicine  
Journal
Journal of Prosthodontics
Publisher
Wiley
ISSN
1532-849X
1059-941X
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify