Myoelectric activity in the intestines of healthy dairy cows during the recovery period after implantation of permanent electrodes.
Options
BORIS DOI
Publisher DOI
PubMed ID
15198220
Description
Objective
To describe myoelectric patterns in the intestines of cows after electrode implantation.Animals
7 lactating Simmental-Red Holstein cows.Procedure
Cows were implanted with 7 pairs of bipolar silver electrodes (1 each in the ileum, cecum, and proximal loop of the ascending colon (PLAC) and 4 in the spiral colon). Myoelectric activity was monitored during 10 periods within the first 3 weeks after surgery. Recordings from the first 2 weeks were compared with recordings from the third week, which was considered a steady-state condition.Results
Significant changes over time were detected for 18 of 57 variables, including 3 variables describing myoelectric activity of the ileum, 6 variables of the cecum, 6 variables of the PLAC, and 3 variables of the spiral colon. Compared with values for the steady-state condition, 16 variables differed significantly for the 14-day period after surgery (7 variables until day 11, 2 variables until day 8, 4 variables until day 5, 1 variable until day 3, and 2 variables until day 2 after electrode implantation). None of the variables had significant changes that lasted only 1 day after surgery.Conclusions And Clinical Relevance
Significant changes were observed for several variables of myoelectric activity in all intestinal segments until as late as 11 days after electrode implantation, whereas a steady-state condition was reached 14 days after surgery. Effects of drugs, manipulations, or nutrition regimens on myoelectric activity of the bovine digestive tract should be evaluated no sooner than 2 weeks after electrode implantation.
To describe myoelectric patterns in the intestines of cows after electrode implantation.Animals
7 lactating Simmental-Red Holstein cows.Procedure
Cows were implanted with 7 pairs of bipolar silver electrodes (1 each in the ileum, cecum, and proximal loop of the ascending colon (PLAC) and 4 in the spiral colon). Myoelectric activity was monitored during 10 periods within the first 3 weeks after surgery. Recordings from the first 2 weeks were compared with recordings from the third week, which was considered a steady-state condition.Results
Significant changes over time were detected for 18 of 57 variables, including 3 variables describing myoelectric activity of the ileum, 6 variables of the cecum, 6 variables of the PLAC, and 3 variables of the spiral colon. Compared with values for the steady-state condition, 16 variables differed significantly for the 14-day period after surgery (7 variables until day 11, 2 variables until day 8, 4 variables until day 5, 1 variable until day 3, and 2 variables until day 2 after electrode implantation). None of the variables had significant changes that lasted only 1 day after surgery.Conclusions And Clinical Relevance
Significant changes were observed for several variables of myoelectric activity in all intestinal segments until as late as 11 days after electrode implantation, whereas a steady-state condition was reached 14 days after surgery. Effects of drugs, manipulations, or nutrition regimens on myoelectric activity of the bovine digestive tract should be evaluated no sooner than 2 weeks after electrode implantation.
Date of Publication
2004-06
Publication Type
Article
Language(s)
en
Additional Credits
Series
American Journal of Veterinary Research
Publisher
American Veterinary Medical Association
ISSN
0002-9645
Access(Rights)
restricted