• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Dynamic intraligamentary stabilization of anterior cruciate ligament repair: hardware removal has no effect on knee laxity at 2-year follow-up.
 

Dynamic intraligamentary stabilization of anterior cruciate ligament repair: hardware removal has no effect on knee laxity at 2-year follow-up.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.125039
Publisher DOI
10.1007/s00402-019-03113-x
PubMed ID
30649589
Description
INTRODUCTION

Dynamic intraligamentary stabilization (DIS) stabilizes the knee joint during anterior cruciate ligament (ACL) healing. After 6 months, tibial hardware removal is offered to the patients if local discomfort at the implant site is present.

AIM

This study compared knee laxity and functional scores 2 years after DIS between patients with and without hardware removal. It is hypothesized that it does not affect ACL healing.

MATERIALS AND METHODS

The study retrospectively analyzed prospectively collected data from 173 patients with either hardware removal (n = 47) or no additional intervention (n = 126). Inverse probability of treatment weighting using the propensity score was applied to balance the groups for baseline characteristics. The primary outcome was the side-to-side difference in knee laxity measured with the rolimeter at manual maximum force (Δ-Lachman). Secondary outcomes were the pivot-shift test and subjective scores.

RESULTS

Mean age was 34 years in both groups, and female gender was 47% (hardware removal group) and 50% (control group), respectively. No significant differences were found for Δ-Lachman (p = 0.09), pivot-shift test (p = 0.41), and subjective scores (p > 0.10) two years after DIS.

CONCLUSION

Knee laxity 2 years after DIS in patients with tibial hardware removal and patients without hardware removal was not significantly different. The groups were also similar regarding all the assessed functional scores. This study confirms the hypothesis that the healing ACL resumes its stabilizing role, and the hardware can be removed beginning 6 months after surgery without adverse consequences for joint stability.

LEVEL OF EVIDENCE

Case-control study, Level III.
Date of Publication
2019-05
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
300 Social sciences, sociology & anthropology > 360 Social problems & social services
Keyword(s)
ACL Dynamic intraligamentary stabilization Hardware removal Knee laxity Lachman Ligamys
Language(s)
en
Contributor(s)
Häberli, Janosch
Bieri, Kathrinorcid-logo
Institut für Sozial- und Präventivmedizin (ISPM)
Aghayev, Emin
Institut für Sozial- und Präventivmedizin (ISPM)
Eggli, Stefan
Henle, Philipp
Additional Credits
Institut für Sozial- und Präventivmedizin (ISPM)
Series
Archives of orthopaedic and trauma surgery
Publisher
Springer
ISSN
0936-8051
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo