• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Evaluation and optimization of novel extraction algorithms for the automatic detection of atrial activations recorded within the pulmonary veins during atrial fibrillation.
 

Evaluation and optimization of novel extraction algorithms for the automatic detection of atrial activations recorded within the pulmonary veins during atrial fibrillation.

Options
  • Details
  • Files
BORIS DOI
10.48350/172493
Publisher DOI
10.1186/s12911-022-01969-5
PubMed ID
36031620
Description
BACKGROUND AND OBJECTIVE

The automated detection of atrial activations (AAs) recorded from intracardiac electrograms (IEGMs) during atrial fibrillation (AF) is challenging considering their various amplitudes, morphologies and cycle length. Activation time estimation is further complicated by the constant changes in the IEGM active zones in complex and/or fractionated signals. We propose a new method which provides reliable automatic extraction of intracardiac AAs recorded within the pulmonary veins during AF and an accurate estimation of their local activation times.

METHODS

First, two recently developed algorithms were evaluated and optimized on 118 recordings of pulmonary vein IEGM taken from 35 patients undergoing ablation of persistent AF. The adaptive mathematical morphology algorithm (AMM) uses an adaptive structuring element to extract AAs based on their morphological features. The relative-energy algorithm (Rel-En) uses short- and long-term energies to enhance and detect the AAs in the IEGM signals. Second, following the AA extraction, the signal amplitude was weighted using statistics of the AA sequences in order to reduce over- and undersensing of the algorithms. The detection capacity of our algorithms was compared with manually annotated activations and with two previously developed algorithms based on the Teager-Kaiser energy operator and the AF cycle length iteration, respectively. Finally, a method based on the barycenter was developed to reduce artificial variations in the activation annotations of complex IEGM signals.

RESULTS

The best detection was achieved using Rel-En, yielding a false negative rate of 0.76% and a false positive rate of only 0.12% (total error rate 0.88%) against expert annotation. The post-processing further reduced the total error rate of the Rel-En algorithm by 70% (yielding to a final total error rate of 0.28%).

CONCLUSION

The proposed method shows reliable detection and robust temporal annotation of AAs recorded within pulmonary veins in AF. The method has low computational cost and high robustness for automatic detection of AAs, which makes it a suitable approach for online use in a procedural context.
Date of Publication
2022-08-28
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Activation detection Atrial fibrillation Biomedical signal processing Intracardiac electrograms Non-linear signal processing
Language(s)
en
Contributor(s)
Prudat, Yann
Luca, Adrian
Yazdani, Sasan
Derval, Nicolas
Jaïs, Pierre
Roten, Laurentorcid-logo
Universitätsklinik für Kardiologie
Berte, Benjamin
Pruvot, Etienne
Vesin, Jean-Marc
Pascale, Patrizio
Additional Credits
Universitätsklinik für Kardiologie
Series
BMC medical informatics and decision making
Publisher
BioMed Central
ISSN
1472-6947
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo