Publication:
Effect of polishing and denture cleansers on the surface roughness of new-generation denture base materials and their color change after cleansing.

cris.virtual.author-orcid0000-0001-9700-5534
cris.virtualsource.author-orcidb17aa95e-8613-4e8c-95f4-fb59b57fd1fb
cris.virtualsource.author-orcid83434b8a-da94-4aac-9166-d2c7ae8834e7
cris.virtualsource.author-orcida1c05580-bb43-487f-b66e-1f95152ea447
cris.virtualsource.author-orcidd9b3fb3e-540e-4774-ab66-db6dccec7678
cris.virtualsource.author-orcidf32a2cb1-9679-4acd-9e86-2065b98dff4a
datacite.rightsopen.access
dc.contributor.authorCakmak, Gülce
dc.contributor.authorHess, Julia Anouk
dc.contributor.authorDönmez, Mustafa-Borga
dc.contributor.authorYılmaz, Deniz
dc.contributor.authorAlhotan, Abdulaziz
dc.contributor.authorSchimmel, Martin
dc.contributor.authorPeutzfeldt, Anne
dc.contributor.authorYilmaz, Burak
dc.date.accessioned2024-10-25T17:42:45Z
dc.date.available2024-10-25T17:42:45Z
dc.date.issued2024
dc.description.abstractPURPOSE To evaluate the effect of polishing and denture cleansers on the surface roughness (Ra ) of new-generation denture base materials that are additively, subtractively, and conventionally fabricated, while also assessing their color change after cleansing. MATERIAL AND METHODS One hundred and fifty disk-shaped specimens (AE10×2 mm) were prepared from five denture base materials (one subtractively manufactured nanographene-reinforced prepolymerized polymethylmethacrylate (PMMA) (SM-GC), one subtractively manufactured prepolymerized PMMA (SM-PM), two additively manufactured denture base resins (AM-DT and AM-ND), and one heat-polymerized PMMA (CV) (n = 30). The Ra of the specimens was measured before and after conventional laboratory polishing, while color coordinates were measured after polishing. Specimens were then divided into three subgroups based on the denture cleanser: distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet (n = 10). The Ra and color coordinates were remeasured after nine cleaning cycles over a period of 20 days. The CIEDE200 formula was used to calculate the color differences (ΔE00 ). Two-way analysis of variance (ANOVA) was used to analyze the Ra values before (n = 30) and after (n = 10) cleansing, while repeated measures ANOVA was used to analyze the Ra of material-time point pairs within each denture cleanser (n = 10). ΔE00 data after denture cleansing was also analyzed by using two-way ANOVA (n = 10) (α = .05). RESULTS Before polishing, Ra varied significantly among the materials. SM-GC and SM-PM had the lowest and AM-ND the highest Ra values (P<.001). Polishing significantly reduced Ra of all materials (P<.001), and after polishing, Ra differences among materials were nonsignificant (P≥.072). Regardless of the denture cleanser, the Ra of AM-DT, AM-ND, and CV was the highest before polishing when different time points were considered (P<.001). After cleansing, AM-ND had the highest Ra of all the materials, regardless of the cleanser (P≤.017). AM-DT had higher Ra than SM-PM when distilled water (P = .040) and higher Ra than SM-GC, SM-PM, and CV when NaOCl was used (P<.001). The type of cleanser significantly influenced the Ra of AM-DT, AM-ND, and CV. For AM-DT, NaOCl led to the highest Ra and the tablet led to the lowest Ra (P≤.042), while for AM-ND, distilled water led to the lowest Ra (P≤.024). For CV, the tablet led to lower Ra than distilled water (P = .009). Color change varied among the materials. When distilled water was used, SM-GC had higher ΔE00 than SM-PM and AM-DT (P≤.034). When NaOCl was used, AM-ND had higher ΔE00 than SM-GC, SM-PM, and AM-DT, while CV and SM-GC had higher ΔE00 than SM-PM and AM-DT (P≤.039). Finally, when the tablet was used, AM-ND and CV had the highest ΔE00 , while AM-DT had lower ΔE00 than SM-GC (P≤.015). CONCLUSIONS The tested materials had unacceptable surface roughness (>0.2 μm) before polishing. Roughness decreased significantly after polishing (<0.2 μm). Denture cleansers did not significantly affect the surface roughness of the materials, and roughness remained clinically acceptable after cleansing (<0.2 μm). Considering previously reported color thresholds, AM-ND and CV had unacceptable color change regardless of the denture cleanser, and the effervescent tablet led to perceptible, but acceptable color change for SM-GC, SM-PM, and AM-DT. This article is protected by copyright. All rights reserved.
dc.description.sponsorshipZahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
dc.description.sponsorshipZahnmedizinische Kliniken (ZMK) - Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
dc.description.sponsorshipZahnmedizinische Kliniken (ZMK) Universität Bern
dc.identifier.doi10.48350/185756
dc.identifier.pmid37624691
dc.identifier.publisherDOI10.1111/jopr.13755
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/169529
dc.language.isoen
dc.publisherWiley
dc.relation.ispartofJournal of prosthodontics
dc.relation.issn1532-849X
dc.relation.organizationDCD5A442BE8FE17DE0405C82790C4DE2
dc.relation.organization2897F63CA3F0484BE053960C5C822C63
dc.relation.organizationDCD5A442BD25E17DE0405C82790C4DE2
dc.subjectAdditive manufacturing chemical disinfection color change denture base surface roughness
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleEffect of polishing and denture cleansers on the surface roughness of new-generation denture base materials and their color change after cleansing.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage790
oaire.citation.issue8
oaire.citation.startPage783
oaire.citation.volume33
oairecerif.author.affiliationZahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
oairecerif.author.affiliationZahnmedizinische Kliniken (ZMK) Universität Bern
oairecerif.author.affiliationZahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
oairecerif.author.affiliationZahnmedizinische Kliniken (ZMK) - Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
oairecerif.author.affiliationZahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
oairecerif.author.affiliation2Zahnmedizinische Kliniken (ZMK) Universität Bern
oairecerif.author.affiliation3Zahnmedizinische Kliniken (ZMK) - Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.embargoChanged2024-08-25 22:25:17
unibe.date.licenseChanged2023-08-31 13:49:39
unibe.description.ispublishedpub
unibe.eprints.legacyId185756
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
Journal_of_Prosthodontics_-_2023_-_akmak.pdf
Size:
983.58 KB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
accepted

Collections