  3. Biomechanical comparison of different surface modifications for dental implants
 

Biomechanical comparison of different surface modifications for dental implants

Options
  • Details
Official URL
http://www.quintpub.com/journals/omi/abstract.php?iss2_id=299&article_id=3705
PubMed ID
19216272
Description
Purpose: A satisfactory clinical outcome in dental implant treatment relies on primary stability for immediate load bearing. While the geometric design of an implant contributes to mechanical stability, the nature of the implant surface itself is also critically important. Biomechanical and microcomputerized tomographic evaluation of implant osseointegration was performed to compare alternative structural, chemical and biochemical, and/or pharmaceutical surface treatments applied to an identical established implant design. Materials and Methods: Dental implants with the same geometry but with 6 different surface treatments were tested in vivo in a sheep model (pelvis). Peri-implant bone density and removal torque were compared at 2, 4, and 8 weeks after implantation. Implant surfaces tested were: sandblasted and acid-etched titanium (Ti), sandblasted and etched zirconia, Ti coated with calcium phosphate (CaP), Ti modified via anodic plasma-chemical treatment (APC), bisphosphonate-coated Ti (Ti + Bisphos), and Ti coated with collagen containing chondroitin sulfate (CS). Results: All dental implants were well integrated at the time of sacrifice. There were no significant differences observed in peri-implant bone density between implant groups. After 8 weeks of healing, removal torque values for Ti, Ti + CaP, Ti + Bisphos, and Ti + collagen + CS were significantly higher than those for zirconia and Ti + APC. Conclusions: Whereas the sandblasted/acid-etched Ti implant can still be considered the reference standard surface for dental implants, functional surface modifications such as bisphosphonate or collagen coating seem to enhance early peri-implant bone formation and should be studied further.
Date of Publication
2008
Publication Type
Article
Subject(s)
500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Ferguson, Stephen John
Institut für chirurgische Technologien und Biomechanik (ISTB)
Langhoff, Jens D
Voelter, Katrin
von Rechenberg, Brigitte
Scharnweber, Dieter
Bierbaum, Susanne
Schnabelrauch, Matthias
Kautz, Armin R
Frauchiger, Vinzenz M
Mueller, Thomas L
van Lenthe, G. Harry
Schlottig, Falko
Additional Credits
Institut für chirurgische Technologien und Biomechanik (ISTB)
Series
International journal of oral & maxillofacial implants
Publisher
Quintessence Publ.
ISSN
0882-2786
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo