OBJECTIVES

To report the mid-term results of aortic root replacement using a self-assembled biological composite graft, consisting of a vascular tube graft and a stented tissue valve.

METHODS

Between January 2005 and December 2011, 201 consecutive patients [median age 66 (interquartile range, IQR, 55-77) years, 31 female patients (15.4%), median logistic EuroSCORE 10 (IQR 6.8-23.2)] underwent aortic root replacement using a stented tissue valve for the following indications: annulo-aortic ectasia or ascending aortic aneurysm with aortic valve disease in 162 (76.8%) patients, active infective endocarditis in 18 (9.0%) and acute aortic dissection Stanford type A in 21 (10.4%). All patients underwent clinical and echocardiographic follow-up. We analysed survival and valve-related events.

RESULTS

The overall in-hospital mortality rate was 4.5%. One- and 5-year cardiac-related mortality rates were 3 and 6%, and overall survival was 95 ± 1.5 and 75 ± 3.6%, respectively. The rate of freedom from structural valve failure was 99% and 97 ± 0.4% at the 1- and 5-year follow-up, respectively. The incidence rates of prosthetic valve endocarditis were 3 and 4%, respectively. During a median follow-up of 28 (IQR 14-51) months, only 2 (1%) patients required valve-related redo surgery due to prosthetic valvular endocarditis and none suffered from thromboembolic events. One percent of patients showed structural valve deterioration without any clinical symptoms; none of the patients suffered greater than mild aortic regurgitation.

CONCLUSIONS

Aortic root replacement using a self-assembled biological composite graft is an interesting option. Haemodynamic results are excellent, with freedom from structured valve failure. Need for reoperation is extremely low, but long-term results are necessary to prove the durability of this concept.
Date of Publication
2014-10
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Aortic root replacement
•
Biological valve
•
Echocardiography
•
Results
Language(s)
en
Contributor(s)
Meszaros, Katharina
Liniger, Sophia
Czerny, Martin
Universitätsklinik für Herz- und Gefässchirurgie
Stanger, Olaf
Universitätsklinik für Herz- und Gefässchirurgie
Reineke, David Christian
Universitätsklinik für Herz- und Gefässchirurgie
Englberger, Lars
Universitätsklinik für Herz- und Gefässchirurgie
Carrel, Thierry
Universitätsklinik für Herz- und Gefässchirurgie
Additional Credits
Universitätsklinik für Herz- und Gefässchirurgie
Series
Interactive cardiovascular and thoracic surgery
Publisher
Oxford University Press
ISSN
1569-9293
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo