• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Watchman FLX versus Watchman 2.5 for left atrial appendage closure: a propensity score-matched analysis.
 

Watchman FLX versus Watchman 2.5 for left atrial appendage closure: a propensity score-matched analysis.

Options
  • Details
Publisher DOI
10.4244/EIJ-D-25-00757
PubMed ID
41489742
Description
Background
Evidence supporting the clinical superiority of the Watchman FLX with respect to its previous iteration, the Watchman 2.5, is still sparse.Aims
We aimed to compare the Watchman FLX and Watchman 2.5 in terms of device-related complications and clinical outcomes.Methods
All consecutive left atrial appendage closures (LAACs) completed with implantation of a Watchman device at two high-volume centres between July 2018 and January 2023 were considered. Based on the type of implanted device, patients were assigned to either the Watchman FLX or Watchman 2.5 group. The study endpoints included device-related thrombus (DRT) and peridevice leak (PDL), as evaluated by transoesophageal echocardiography (TOE), and stroke rate at the longest available follow-up. Propensity score matching (PSM) analysis was used to minimise baseline differences between groups.Results
After performing PSM, 1,128 patients were included in each group. In the TOE follow-up, performed at a mean of 2.3 months, both DRT (0.2% vs 3.1%; hazard ratio [HR] 0.35, 95% confidence interval [CI]: 0.21-0.38; p=0.017) and PDL (21.0% vs 30.6%; HR 0.68, 95% CI: 0.59-0.77; p=0.031) were significantly lower in the Watchman FLX group compared with the Watchman 2.5 group. At a mean of 1.6 years of follow-up, the stroke rate was numerically lower in the Watchman FLX group compared with the Watchman 2.5 group (3.4% vs 5.1%; HR 0.56, 95% CI: 0.15-1.69; p=0.078).Conclusions
In a large dual-centre cohort of consecutive, successful LAAC procedures using two iterations of the Watchman device, the Watchman FLX was associated with significantly lower rates of both DRT and PDL compared to the Watchman 2.5.
Date of Publication
2025-12-15
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Galea, Roberto
Clinic of Cardiology
La Fazia, Vincenzo Mirco
Della Rocca, Domenico Giovanni
Gasys, Antanas
Clinic of Cardiology
Bini, Tommaso
Clinic of Cardiology
Graduate School for Health Sciences (GHS)
Siontis, George C M
Clinic of Cardiology
Gianni, Carola
Roten, Laurent
Clinic of Cardiology
Mohanty, Sanghamitra
Brugger, Nicolas
Clinic of Cardiology
Torlapati, Prem Geeta
Horton, Rodney
Al-Ahmad, Amin
Biase, Luigi Di
Natale, Andrea
Räber, Lorenz
Clinic of Cardiology
Additional Credits
Graduate School for Health Sciences (GHS)
Clinic of Cardiology
Clinic of Cardiology
Series
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
Publisher
Société Europa édition
ISSN
1969-6213
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo