  3. Zirconia, titanium, and polyetheretherketone implant abutments show equal long-term clinical success-A systematic review and network meta-analysis.
 

Zirconia, titanium, and polyetheretherketone implant abutments show equal long-term clinical success-A systematic review and network meta-analysis.

Options
  • Details
  • Files
BORIS DOI
10.48620/93170
Publisher DOI
10.1111/prd.70018
PubMed ID
41326963
Description
Hundreds of millions of people have one or more missing teeth. Consequently, a substantial number of patients undergo implant therapy each year. However, technical complications and soft tissue inflammation associated with the implant abutment or the type of restoration can lead to bone loss and, ultimately, implant failure. Using the methodology of network meta-analysis to rigorously compare and contrast the clinical performance of the three commonly used abutment materials: titanium (Ti), zirconium (Zr), and polyetheretherketone (PEEK) polymer. Until May 2025, a systematic search was performed in MEDLINE (PubMed), EMBASE, Scopus, and CENTRAL to find clinical studies comparing Ti, Zr, and PEEK implant abutments. Case reports, case series, in vitro, and in vivo studies were excluded. The Risk of Bias Tool 2, ROBINS-I, and GRADE approaches were used for quality and certainty assessment. Thirty-four articles (950 patients) were included, with various follow-ups. All abutments had high survival rates and no significant differences in marginal bone loss (BL), probing depth (PD), bleeding on probing (BOP), and plaque index (PI). There was no significant difference between Zr and Ti for papillary index (PAP), with a general trend toward better results in Zr, which may be of clinical significance. There was a statistically significant difference in soft tissue discoloration (ΔE) values and technical complications of Zr versus Ti [MD: -2.03, CI: -3.89 to -0.18] and [OR: 0.26, CI: 0.09 to 0.72], respectively, indicating better esthetics and fewer technical complications in Zr. Both Ti and Zr are clinically successful and biologically acceptable. PEEK abutments demonstrated comparable characteristics with both Ti and Zr. However, more studies about PEEK and cost-effectiveness analyses should also be performed to find the best options for clinical applications. PEEK can be a good alternative to Ti and Zr abutments for single-tooth replacement in the anterior and premolar regions.
Date of Publication
2025-12-01
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
bleeding on probing
•
discoloration
•
failure
•
marginal bone loss
•
papillary index
•
probing depth
•
technical complication
Language(s)
en
Contributor(s)
Al-Mohammad, Yasir Nabeel
Kelly, Caroline
Martinekova, Petrana
Wenning, Alexander Schulze
Kiss-Dala, Szilvia
Gede, Noémi
Kerémi, Beáta
Németh, Zsolt
Hermann, Péter
Czumbel, László Márk
Mikulás, Krisztina
Hegyi, Péter
Sculean, Anton
School of Dental Medicine
School of Dental Medicine, Clinic of Periodontology
Varga, Gábor
Additional Credits
School of Dental Medicine
School of Dental Medicine, Clinic of Periodontology
Series
Periodontology 2000
Publisher
Wiley
ISSN
1600-0757
0906-6713
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo