• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Safety of the Solitaire 4 × 40 mm Stent Retriever in the Treatment of Ischemic Stroke.
 

Safety of the Solitaire 4 × 40 mm Stent Retriever in the Treatment of Ischemic Stroke.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.105254
Publisher DOI
10.1007/s00270-017-1785-z
PubMed ID
28864867
Description
PURPOSE

Stent retrievers apply mechanical force to the intracranial vasculature. Our aim was to evaluate the safety and efficacy of the long Solitaire 4 × 40 mm stent retriever for large vessel occlusion in stroke patients.

METHODS

We conducted a retrospective analysis of all patients treated for acute ischemic large vessel occlusion stroke with the Solitaire 2 FR 4 × 40 device between May and October 2016 at our institution. Patient-specific data at baseline and at discharge were documented. Reperfusion was graded with the thrombolysis in cerebral infarction (TICI) classification. Postinterventional angiograms and follow-up cross-sectional imaging were used to evaluate complications.

RESULTS

TICI 2b/3 recanalization was achieved in 20 of 23 patients (87.0%), in 17 patients with the first retriever pass. NIHSS improved from a mean score at presentation of 16 (range 4-36) to 11 (range 0-41) at discharge. Mean mRS score at discharge was 3 (range 0-6) and 3 (range 0-6) at 90 days post-treatment. No infarcts in other territories were observed. One patient showed a (reversible) vasospasm in the postinterventional angiogram and another a small contrast extravasation in follow-up imaging.

CONCLUSION

The Solitaire 2 FR 4 × 40 stent retriever is a safe and efficient device for large vessel occlusion acute ischemic stroke with a high recanalization rate and a low peri- and postinterventional complication rate together with a good clinical outcome. Despite potentially higher friction and shearing forces, no increased incidence of visible damage to the vessel wall was observed.
Date of Publication
2018-01
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Friction force Mechanical forces Reports of complications Straightening of vessel course
Language(s)
en
Contributor(s)
Zibold, Felix
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Mordasini, Pasquale Renato
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Mosimann, Pascal John
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Piechowiak, Eike Immo
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Dobrocky, Tomas
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Fischer, Urs Martin
Universitätsklinik für Neurologie
Arnold, Marcel
Universitätsklinik für Neurologie
Bellwald, Sebastian
Universitätsklinik für Neurologie
Gralla, Jan
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Additional Credits
Universitätsklinik für Neurologie
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Series
Cardiovascular and interventional radiology
Publisher
Springer
ISSN
0174-1551
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo