Early Loading of Titanium Dental Implants with an Intraoperatively Conditioned Hydrophilic Implant Surface: 3-Year Results of a Prospective Case Series Study.
Options
BORIS DOI
Publisher DOI
PubMed ID
32991653
Description
PURPOSE
The hydrophilic implant surface (INICELL) is a chemical alteration of a sandblasted and thermally acid-etched surface that should lead to long-term osseointegration. This study investigated 3-year results after early loading of implants with a hydrophilic, moderately rough surface in occlusal contact.
MATERIALS AND METHODS
This prospective case series study was conducted in subjects with partially edentulous mandibles. Implants were placed on day 21 and loaded with a provisional reconstruction after at least 21 days of healing (baseline, day 0) if their implant stability quotient (ISQ) was ≥ 70 (mean of three measurements) and were replaced by definitive porcelain-fused-to-metal prostheses at the 6-month follow-up visit. Follow-up examinations were planned 1, 3, 6, 12, and 36 months after baseline.
RESULTS
A total of 20 implants were placed in 15 patients (mean age: 51 years, range: 32 to 67 years). After 36 months, all implants were osseointegrated, and no suppuration was recorded. Small changes of bone level were observed between 3 months and 36 months. At 36 months, the median values of the 20 implants were 0.25 (range: 0 to 0.5, SD: 0.17), 0.25 (range: 0 to 1, SD: 0.27), and 4 (range: 2 to 7.25, SD: 1.17) for the mean modified Plaque Index (mPI), mean modified Sulcus Bleeding Index (mSBI), and mean probing pocket depth, respectively. The pairwise analysis between 3 and 36 months showed an improvement in the mean mPI (P = .0126) and mean mSBI (P = .0059). After 36 months, all patients (n = 15) were fully satisfied with a mean of 9.43 (range: 8 to 10, SD: 0.678) at the visual analog scale.
CONCLUSION
Early functional loading of implants with a hydrophilic, moderately rough outer surface in occlusal contact 21 days after healing appears to be a safe and feasible treatment option when placed in the posterior mandible of partially edentulous patients.
The hydrophilic implant surface (INICELL) is a chemical alteration of a sandblasted and thermally acid-etched surface that should lead to long-term osseointegration. This study investigated 3-year results after early loading of implants with a hydrophilic, moderately rough surface in occlusal contact.
MATERIALS AND METHODS
This prospective case series study was conducted in subjects with partially edentulous mandibles. Implants were placed on day 21 and loaded with a provisional reconstruction after at least 21 days of healing (baseline, day 0) if their implant stability quotient (ISQ) was ≥ 70 (mean of three measurements) and were replaced by definitive porcelain-fused-to-metal prostheses at the 6-month follow-up visit. Follow-up examinations were planned 1, 3, 6, 12, and 36 months after baseline.
RESULTS
A total of 20 implants were placed in 15 patients (mean age: 51 years, range: 32 to 67 years). After 36 months, all implants were osseointegrated, and no suppuration was recorded. Small changes of bone level were observed between 3 months and 36 months. At 36 months, the median values of the 20 implants were 0.25 (range: 0 to 0.5, SD: 0.17), 0.25 (range: 0 to 1, SD: 0.27), and 4 (range: 2 to 7.25, SD: 1.17) for the mean modified Plaque Index (mPI), mean modified Sulcus Bleeding Index (mSBI), and mean probing pocket depth, respectively. The pairwise analysis between 3 and 36 months showed an improvement in the mean mPI (P = .0126) and mean mSBI (P = .0059). After 36 months, all patients (n = 15) were fully satisfied with a mean of 9.43 (range: 8 to 10, SD: 0.678) at the visual analog scale.
CONCLUSION
Early functional loading of implants with a hydrophilic, moderately rough outer surface in occlusal contact 21 days after healing appears to be a safe and feasible treatment option when placed in the posterior mandible of partially edentulous patients.
Date of Publication
2020
Publication Type
Article
Subject(s)
Language(s)
en
Contributor(s)
Series
The international journal of oral & maxillofacial implants
Publisher
Quintessence Publishing
ISSN
1942-4434
Access(Rights)