Bivalirudin for Alternative Anticoagulation in Extracorporeal Membrane Oxygenation: A Systematic Review.
Options
Publisher DOI
PubMed ID
27356945
Description
BACKGROUND
Extracorporeal membrane oxygenation (ECMO) offers therapeutic options in refractory respiratory and/or cardiac failure. Systemic anticoagulation with heparin is routinely administered. However, in patients with heparin-induced thrombocytopenia or heparin resistance, the direct thrombin inhibitor bivalirudin is a valid option and has been increasingly used for ECMO anticoagulation. We aimed at evaluating its safety and its optimal dosing for ECMO.
METHODS
Systematic web-based literature search of PubMed and EMBASE performed via National Health Service Library Evidence and manually, updated until January 30, 2016.
RESULTS
The search revealed 8 publications relevant to the topic (5 case reports). In total, 58 patients (24 pediatrics) were reported (18 received heparin as control groups). Bivalirudin was used with or without loading dose, followed by infusion at different ranges (lowest 0.1-0.2 mg/kg/h without loading dose; highest 0.5 mg/kg/h after loading dose). The strategies for monitoring anticoagulation and optimal targets were dissimilar (activated partial thromboplastin time 45-60 seconds to 42-88 seconds; activated clotting time 180-200 seconds to 200-220 seconds; thromboelastography in 1 study).
CONCLUSION
Bivalirudin loading dose was not always used; infusion range and anticoagulation targets were different. In this systematic review, we discuss the reasons for this variability. Larger studies are needed to establish the optimal approach with the use of bivalirudin for ECMO.
Extracorporeal membrane oxygenation (ECMO) offers therapeutic options in refractory respiratory and/or cardiac failure. Systemic anticoagulation with heparin is routinely administered. However, in patients with heparin-induced thrombocytopenia or heparin resistance, the direct thrombin inhibitor bivalirudin is a valid option and has been increasingly used for ECMO anticoagulation. We aimed at evaluating its safety and its optimal dosing for ECMO.
METHODS
Systematic web-based literature search of PubMed and EMBASE performed via National Health Service Library Evidence and manually, updated until January 30, 2016.
RESULTS
The search revealed 8 publications relevant to the topic (5 case reports). In total, 58 patients (24 pediatrics) were reported (18 received heparin as control groups). Bivalirudin was used with or without loading dose, followed by infusion at different ranges (lowest 0.1-0.2 mg/kg/h without loading dose; highest 0.5 mg/kg/h after loading dose). The strategies for monitoring anticoagulation and optimal targets were dissimilar (activated partial thromboplastin time 45-60 seconds to 42-88 seconds; activated clotting time 180-200 seconds to 200-220 seconds; thromboelastography in 1 study).
CONCLUSION
Bivalirudin loading dose was not always used; infusion range and anticoagulation targets were different. In this systematic review, we discuss the reasons for this variability. Larger studies are needed to establish the optimal approach with the use of bivalirudin for ECMO.
Date of Publication
2016-06-29
Publication Type
Article
Subject(s)
Keyword(s)
ECMO
•
HIT
•
cardiopulmonary bypass
•
direct thrombin inhibitor
•
heparin-induced thrombocytopenia
Language(s)
en
Contributor(s)
Sanfilippo, Filippo | |
Asmussen, Sven | |
Maybauer, Dirk M | |
Santonocito, Cristina | |
Fraser, John F | |
Maybauer, Marc O |
Additional Credits
Series
Journal of intensive care medicine
Publisher
Sage
ISSN
1525-1489
Access(Rights)
metadata.only