A cost-effective surgical navigation solution for periacetabular osteotomy (PAO) surgery

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.75233
Publisher DOI
10.1007/978-3-319-23482-3_16
Description
In this chapter a low-cost surgical navigation solution for periacetabular osteotomy (PAO) surgery is described. Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient’s pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient’s anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient’s pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography (CT) scan is used to visualize the updated orientation of the acetabular fragment. Experiments with plastic bones (7 hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistical difference on the measurement of acetabular component reorientation (anteversion and inclination). In six out of seven hip joints the mean absolute difference was below five degrees for both anteversion and inclination.
Date of Publication
2016
Publication Type
Book Section
Subject(s)
600 Technology > 610 Medicine & health
500 Science > 570 Life sciences; biology
Language(s)
en
Contributor(s)
Pflugi, Silvio
Institut für chirurgische Technologien und Biomechanik (ISTB)
Liu, Li
Institut für chirurgische Technologien und Biomechanik (ISTB)
Ecker, Timo Michael
Universitätsklinik für Orthopädische Chirurgie und Traumatologie
Cullmann, Jennifer
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie
Siebenrock, Klaus-Arno
Universitätsklinik für Orthopädische Chirurgie und Traumatologie
Zheng, Guoyanorcid-logo
Institut für chirurgische Technologien und Biomechanik (ISTB)
Editor(s)
Zheng, Guoyan
Li, Shuo
Additional Credits
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie
Universitätsklinik für Orthopädische Chirurgie und Traumatologie
Institut für chirurgische Technologien und Biomechanik (ISTB)
Publisher
Springer
ISSN
2212-9391
ISBN
978-3-319-23481-6
Book Title
Computational Radiology for Orthopaedic Interventions
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo