• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial
 

Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.39143
Publisher DOI
10.1016/j.jcin.2013.04.011
PubMed ID
23968698
Description
OBJECTIVES

This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial.

BACKGROUND

The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES.

METHODS

The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat.

RESULTS

At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005).

CONCLUSIONS

The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220).
Date of Publication
2013-08
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
300 Social sciences, sociology & anthropology > 360 Social problems & social services
Keyword(s)
ACS
•
ARC
•
Academic Research Consortium
•
BES
•
BMS
•
CI
•
DES
•
KM
•
Kaplan-Meier
•
MACE
•
MI
•
PCI
•
POCE
•
RR
•
SES
•
ST
•
ST-segment elevation myocardial infarction
•
STEMI
•
TVR
•
acute coronary syndrome
•
bare-metal stent(s)
•
biodegradable polymer
•
biolimus-eluting stent(s)
•
confidence interval
•
drug-eluting stent(s)
•
drug-eluting stents
•
durable polymer
•
major adverse cardiac events
•
myocardial infarction
•
patient-oriented composite endpoint
•
percutaneous coronary intervention
•
rate ratio(s)
•
sirolimus-eluting stent(s)
•
stent thrombosis
•
target vessel revascularization
Language(s)
en
Contributor(s)
Serruys, Patrick W.
Farooq, Vasim
Kalesan, Bindu
Institut für Sozial- und Präventivmedizin (ISPM)
DKF CTU Bern
de Vries, Ton
Buszman, Pawel
Linke, Axel
Ischinger, Thomas
Klauss, Volker
Eberli, Franz
Wijns, William
Morice, Marie Claude
Di Mario, Carlo
Corti, Roberto
Antoni, Diethmar
Sohn, Hae Y.
Eerdmans, Pedro
Rademaker-Havinga, Tessa
van Es, Gerrit-Anne
Meier, Bernhard
Departement Klinische Forschung, Forschungsgruppe Kardiologie
Jüni, Peter
Institut für Sozial- und Präventivmedizin (ISPM)
DKF CTU Bern
Windecker, Stephan
Departement Klinische Forschung, Forschungsgruppe Kardiologie
Additional Credits
Departement Klinische Forschung, Forschungsgruppe Kardiologie
Institut für Sozial- und Präventivmedizin (ISPM)
Series
JACC. Cardiovascular Interventions
Publisher
Elsevier
ISSN
1876-7605
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo