Publication:
Evaluation of different types of enamel conditioning before application of a fissure sealant

cris.virtual.author-orcid0000-0002-4686-1362
cris.virtualsource.author-orcid7d495582-38b4-4502-959b-332b0f2c99db
cris.virtualsource.author-orcid6854f4e7-b33c-49be-ad91-369c6054ff38
cris.virtualsource.author-orcidd9b3fb3e-540e-4774-ab66-db6dccec7678
cris.virtualsource.author-orcid6374ed29-695a-4f29-a8fb-dfd77c0b4972
datacite.rightsopen.access
dc.contributor.authorCiucchi, Philip Ruwan
dc.contributor.authorNeuhaus, Klaus
dc.contributor.authorEmerich, Marta
dc.contributor.authorPeutzfeldt, Anne
dc.contributor.authorLussi, Adrian
dc.date.accessioned2024-10-24T16:38:35Z
dc.date.available2024-10-24T16:38:35Z
dc.date.issued2015-01
dc.description.abstractThe aim of the study was to compare fissure sealant quality after mechanical conditioning of erbium-doped yttrium aluminium garnet (Er:YAG) laser or air abrasion prior to chemical conditioning of phosphoric acid etching or of a self-etch adhesive. Twenty-five permanent molars were initially divided into three groups: control group (n = 5), phosphoric acid etching; test group 1 (n = 10), air abrasion; and test group 2, (n = 10) Er:YAG laser. After mechanical conditioning, the test group teeth were sectioned buccolingually and the occlusal surface of one half tooth (equal to one sample) was acid etched, while a self-etch adhesive was applied on the other half. The fissure system of each sample was sealed, thermo-cycled and immersed in 5% methylene dye for 24 h. Each sample was sectioned buccolingually, and one slice was analysed microscopically. Using specialized software microleakage, unfilled margin, sealant failure and unfilled area proportions were calculated. A nonparametric ANOVA model was applied to compare the Er:YAG treatment with that of air abrasion and the self-etch adhesive with phosphoric acid (α = 0.05). Test groups were compared to the control group using Wilcoxon rank sum tests (α = 0.05). The control group displayed significantly lower microleakage but higher unfilled area proportions than the Er:YAG laser + self-etch adhesive group and displayed significantly higher unfilled margin and unfilled area proportions than the air-abrasion + self-etch adhesive group. There was no statistically significant difference in the quality of sealants applied in fissures treated with either Er:YAG laser or air abrasion prior to phosphoric acid etching, nor in the quality of sealants applied in fissures treated with either self-etch adhesive or phosphoric acid following Er:YAG or air-abrasion treatment.
dc.description.numberOfPages9
dc.description.sponsorshipZahnmedizinische Kliniken, Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
dc.identifier.doi10.7892/boris.77063
dc.identifier.pmid23636296
dc.identifier.publisherDOI10.1007/s10103-013-1333-2
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/138882
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofLasers in medical science
dc.relation.issn0268-8921
dc.relation.organizationDCD5A442BE8FE17DE0405C82790C4DE2
dc.subjectFissure sealants
dc.subjectAir abrasion
dc.subjectEr:YAG laser
dc.subjectSelf-etch adhesive
dc.subjectPhosphoric acid
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleEvaluation of different types of enamel conditioning before application of a fissure sealant
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage9
oaire.citation.issue1
oaire.citation.startPage1
oaire.citation.volume30
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.description.ispublishedpub
unibe.eprints.legacyId77063
unibe.journal.abbrevTitleLASER MED SCI
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Collections