• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Transcatheter Aortic Valve-in-Valve Implantation for Failing Stentless Bioprosthetic Aortic Valves: An International Multicentre Retrospective Analysis.
 

Transcatheter Aortic Valve-in-Valve Implantation for Failing Stentless Bioprosthetic Aortic Valves: An International Multicentre Retrospective Analysis.

Options
  • Details
  • Files
BORIS DOI
10.48620/93153
Publisher DOI
10.1002/ccd.70376
PubMed ID
41332114
Description
Background
Valve-in-valve aortic valve implantation (ViV-TAVI) offers a less invasive treatment option for patients with a failing surgical bioprosthesis, avoiding the need for redo surgery. ViV-TAVI within a stentless bioprosthetic valve poses unique technical challenges. We report an international, multicentre experience evaluating procedural and clinical outcomes for patients undergoing ViV-TAVI for failed stentless bioprosthetic aortic valves.Aims
To evaluate the procedural feasibility, safety, and clinical outcomes of ViV-TAVI performed for failed stentless bioprosthetic aortic valves in an international, multicentre cohort.Methods
We retrospectively analysed 65 patients who underwent ViV-TAVI for stentless valve failure between 2010 and 2024. Outcome endpoints were based on the Valve Academic Research Consortium 3 (VARC-3) criteria.Results
Sixty-five patients (mean age 78.8 ± 10.2 years; 66.1% male; mean STS-PROM 6.9 ± 4.7) were included. The mean interval between surgical valve implantation and failure was 12.9 ± 4.1 years, with regurgitation the predominant mechanism of valve dysfunction (52.3%). Procedural success was achieved in 92.3%. 17 patients (26.2%) had upfront coronary protection. Despite this, six patients required unplanned percutaneous coronary intervention (PCI) for coronary obstruction. The 30-day and 1-year mortality rate was 0% and 8% respectively.Conclusions
ViV-TAVI was an effective intervention for patients with failing stentless bioprosthetic valves, with high procedural success rates despite unique technical challenges. Careful preprocedural imaging, planning, and implementation of coronary protection strategies are critical for optimal patient outcomes.
Date of Publication
2026-02
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
TAVI
•
aortic stenosis
•
coronary obstruction
•
stentless bioprosthesis
•
valve‐in‐valve
Language(s)
en
Contributor(s)
Rayner, Clare
Paleri, Sarang
Satpal, Arri
Tomii, Daijiro
Pilgrim, Thomas
Codner, Pablo
Kornowski, Ran
Mangieri, Antonio
Tartaglia, Francesco
Mauri, Victor
De Backer, Ole
Kobari, Yusuke
Nombela-Franco, Luis
Ielasi, Alfonso
Akodad, Mariama
Sava, Ruxandra
Patterson, Tiffany
Redwood, Simon
Adams, Heath
Additional Credits
Clinic of Cardiology
Series
Catheterization & Cardiovascular Interventions
Publisher
Wiley
ISSN
1522-726X
1522-1946
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo