  3. Multidetector Computed Tomography Imaging: Effect of Sparse Sampling and Iterative Reconstruction on Trabecular Bone Microstructure.
 

Multidetector Computed Tomography Imaging: Effect of Sparse Sampling and Iterative Reconstruction on Trabecular Bone Microstructure.

Options
  • Details
BORIS DOI
10.7892/boris.112716
Date of Publication
February 27, 2018
Publication Type
Article
Division/Institute

Universitätsklinik fü...

Contributor
Mookiah, Muthu Rama Krishnan
Subburaj, Karupppasamy
Mei, Kai
Kopp, Felix K
Kaesmacher, Johannes
Universitätsklinik für Neurologie
Jungmann, Pia M
Foehr, Peter
Noel, Peter B
Kirschke, Jan S
Baum, Thomas
Subject(s)

600 - Technology::610...

Series
Journal of computer assisted tomography
ISSN or ISBN (if monograph)
0363-8715
Publisher
Lippincott Williams & Wilkins
Language
English
Publisher DOI
10.1097/RCT.0000000000000710
PubMed ID
29489591
Description
Multidetector computed tomography-based trabecular bone microstructure analysis ensures promising results in fracture risk prediction caused by osteoporosis. Because multidetector computed tomography is associated with high radiation exposure, its clinical routine use is limited. Hence, in this study, we investigated in 11 thoracic midvertebral specimens whether trabecular texture parameters are comparable derived from (1) images reconstructed using statistical iterative reconstruction (SIR) and filtered back projection as criterion standard at different exposures (80, 150, 220, and 500 mAs) and (2) from SIR-based sparse sampling projections (12.5%, 25%, 50%, and 100%) and equivalent exposures as criterion standard. Twenty-four texture features were computed, and those that showed similar values between (1) filtered back projection and SIR at the different exposure levels and (2) sparse sampling and equivalent exposures and reconstructed with SIR were identified. These parameters can be of equal value in determining trabecular bone microstructure with lower radiation exposure using sparse sampling and SIR.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/159263
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
00004728-900000000-99276.pdftextAdobe PDF716.93 KBpublisherpublished restricted
BORIS Portal
Bern Open Repository and Information System
Build: 960e9e [21.08. 13:49]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo