  3. Feasibility of Smartphone-Derived Short-Interval Walking Tests for Monitoring Functional Recovery After Spine Surgery.
 

Feasibility of Smartphone-Derived Short-Interval Walking Tests for Monitoring Functional Recovery After Spine Surgery.

Options
  • Details
  • Files
BORIS DOI
10.48620/98027
Publisher DOI
10.1002/jsp2.70173
PubMed ID
42022424
Description
Background
Traditional assessments of functional recovery after spine surgery rely on patient-reported outcomes, which are prone to bias. Wearables and smartphone activity tracking offer objective monitoring but may be unreliable if devices are not carried continuously. Capacity-oriented measures, such as the 1-min walk test (1MWT) and 6-min walk test (6MWT), may be more reliable. This study evaluated smartphone-derived interval metrics after lumbar spine surgery retrospectively.Methods
iPhone Health exports from 41 patients were analyzed. A sliding-window algorithm parsed daily distances to simulate 1MWT and 6MWT. Step counts and active time were extracted. Activity was compared across four intervals: 6-month baseline, final 2 weeks preoperatively, early postoperative (0-2 weeks), and late postoperative (2-6 weeks). Paired t-tests or Wilcoxon signed-rank tests were used, with Simes-Hochberg adjustment for multiple comparisons. Day-to-day stability was summarized by the coefficient of variation (CV). Pearson correlations were calculated.Results
Median 1MWT fell from 98 m at baseline to 82 m in the final two preoperative weeks (p < 0.05) and increased to 105 m by late recovery (p < 0.05 vs. preoperative). Median 6MWT declined from 403 to 345 m preoperatively, with this decline not reaching significance (p = 0.07), and increased to 407 m by late recovery (p < 0.05 vs. preoperative). Steps declined from 5030 to 3825 preoperatively (p < 0.05) and rose to 5538 at 2-6 weeks (p < 0.05 vs. preoperative). The 1MWT and 6MWT were strongly correlated. CV was lower for 1MWT and 6MWT than for steps.Conclusions
Smartphone-derived 1MWT and 6MWT improved significantly from the immediate preoperative period to late postoperative recovery, showed lower day-to-day variability than longitudinal activity metrics, and were strongly correlated with each other. These findings support smartphone-derived interval metrics as a feasible method to monitor recovery following lumbar spine surgery.
Date of Publication
2026-03
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Puhakka, J
Jung, M
Fekete, T
Loibl, M
Kleinstück, F
Porchet, F
Ropelato, M
Gocevic, M
Galbusera, F
Cina, A
O'Riordan, D
Kosola, J
Haschtmann, Daniel
Additional Credits
Clinic of Orthopaedic Surgery
Series
JOR Spine
Publisher
Wiley
ISSN
2572-1143
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo