• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Dimensional Stability of Additively Manufactured Dentate Maxillary Diagnostic Casts in Biobased Model Resin.

Dimensional Stability of Additively Manufactured Dentate Maxillary Diagnostic Casts in Biobased Model Resin.

Details
Files
DOI
10.48350/196711
Publisher DOI
10.3390/ma17092128
PubMed ID
38730934
Abstract
This study aimed to evaluate the dimensional stability of maxillary diagnostic casts fabricated from a biobased model resin, which consists of 50% renewable raw materials for sustainable production, a model resin, and stone, over one month. A master maxillary stone cast was digitized with a laboratory scanner to generate a reference file. This master cast was also scanned with an intraoral scanner to additively manufacture casts with a biobased model resin (BAM) and a model resin (AM). Polyvinylsiloxane impressions of the master cast were also made and poured in type III stone (CV) (n = 8). The same laboratory scanner was used to digitize each model one day (T0), 1 week (T1), 2 weeks (T2), 3 weeks (T3), and 4 weeks (T4) after fabrication. Deviations from the reference file were calculated with an analysis software and analyzed with generalized linear model analysis (α = 0.05). The interaction between the material and the time point affected measured deviations (p < 0.001). Regardless of the time point, CV had the lowest and AM had the highest deviations (p < 0.001). BAM mostly had lower deviations at T0 and mostly had higher deviations at T4 (p ≤ 0.011). AM had the highest deviations at T4 and then at T3, whereas it had the lowest deviations at T0 (p ≤ 0.002). The measured deviations of CV increased after each time point (p < 0.001). BAM casts had deviations within the previously reported clinically acceptable thresholds over one month and had acceptable dimensional stability. Therefore, tested biobased resin may be a viable alternative for the sustainable manufacturing of maxillary diagnostic casts that are to be used clinically.
Date Issued
2024-05-01
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
additive manufacturing biobased model resin dental cast dimensional stability sustainable manufacturing
Language(s)
en
Author(s)
Demirel, Münir
Diken Türksayar, Almira Ada
Petersmann, Sandra
Spintzyk, Sebastian
Dönmez, Mustafa Borga  
Zahnmedizinische Kliniken (ZMK) Universität Bern  
Additional Credits
Zahnmedizinische Kliniken (ZMK) Universität Bern  
Journal
Materials
Publisher
MDPI
ISSN
1996-1944
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify