• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Comparison of smartphone-camera and conventional flatbed scanner images for analytical evaluation of chewing function.
 

Comparison of smartphone-camera and conventional flatbed scanner images for analytical evaluation of chewing function.

Options
  • Details
  • Files
BORIS DOI
10.48350/149186
Publisher DOI
10.1111/joor.13094
PubMed ID
32966643
Description
BACKGROUND

The two-colour mixing test is a quick method to assess chewing function (CF). The use of smartphone cameras for acquiring images may help in further simplifying the process.

OBJECTIVE

This study evaluated the reliability of smartphone-camera images of chewing gums to assess CF.

METHODS

Five test samples of a bicoloured chewing gum were produced by a single fully dentate adult volunteer. The specimens were flattened to 1-mm thick wafers. The two sides of the wafers were digitised with a conventional flatbed scanner (control) and were photographed 20 times using 8 different smartphones. The images were assessed optoelectronically to obtain the variance of hue (VoH) and subjectively by visual assessment (SA) using a categorical scale (SA1-SA5). Spearman's correlation and regression models were used for statistical analyses.

RESULTS

The intra-group variability for SA1-SA3 was <1% for all smartphones, but significantly higher than controls for SA4 and SA5 (smartphone: SA4 = 5.57%; SA5 = 8.76%; control: SA4 = 2.5%; SA5 = 0.79%). VoH was progressively lower from SA1 to SA5 for all imaging devices (r > -.97; P < .001). VoH comparisons between control and smartphone images revealed significant differences for the individual SA categories, and however, the magnitude of differences was small and non-significant when the full range of SA levels were considered. The linear mixed model regression showed significant effects for all the smartphones (P < .001) and SA levels (P < .001) in relation to the flatbed scanner values.

CONCLUSIONS

Smartphone cameras may be used to evaluate colour mixture for a bolus-kneading test, however, the precision is lower with higher degrees of colour mixing.
Date of Publication
2020-12
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Chewing function bolus-kneading test chewing gum oral function smartphone cameras two-colour mixing test
Language(s)
en
Contributor(s)
Fankhauser, Nicolas
Kalberer, Nicole
Müller, Frauke
Leles, Claudio R
Schimmel, Martinorcid-logo
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Srinivasan, Murali
Additional Credits
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Series
Journal of oral rehabilitation
Publisher
Wiley
ISSN
1365-2842
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo