  2. Publications
  3. Safety and Effectiveness of Neuro-thrombectomy on Single compared to Biplane Angiography Systems.
 

Safety and Effectiveness of Neuro-thrombectomy on Single compared to Biplane Angiography Systems.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.142010
Publisher DOI
10.1038/s41598-020-60851-4
PubMed ID
32161286
Description
An increasing number of centers not necessarily equipped with biplane (BP) angiosuites are performing mechanical thrombectomy (MT) in acute ischemic stroke patients. We assessed whether MT performed on single-plane (SP) is equivalent in terms of safety, effectiveness, radiation and contrast agent exposure. Consecutive patients treated by MT in four high volume centers between January 2014 and May 2017 were included. Demographic and MT characteristics were assessed and compared between SP and BP. Of 906 patients treated by MT, 576 (64%) were handled on a BP system. After multivariate analysis, contrast load and fluoroscopy duration were significantly lower in the BP group [100vs200mL, relative effect 0.85 (CI: 0.79-0.92), p = 0.0002; 22 vs 27 min, relative effect 0.84 (CI: 0.76-0.93), p = 0.0008, respectively]. There was no difference in recanalization (modified Thrombolysis-In-Cerebral-Infarction 2b-3), good clinical outcome (modified Rankin Scale 0-2), complications rates, procedure duration or radiation exposure. A three-vessel diagnostic angiogram performed prior to MT led to a significant increase in procedure duration (15% increase, p = 0.05), radiation exposure (33% increase, p < 0.0001) and contrast load (125% increase, p < 0.0001). Mechanical neuro-thrombectomy seems equally safe and effective on a single or biplane angiography system despite increased contrast load and fluoroscopy duration on the former.
Date of Publication
2020-03-11
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Guenego, Adrien
Mosimann, Pascal John
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Wintermark, Max
Heit, Jeremy J
Zuber, Kevin
Dobrocky, Tomas
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Lotterie, Jean Albert
Nicholson, Patrick
Marcellus, David G
Olivot, Jean Marc
Gonzalez, Nestor
Blanc, Raphaël
Pereira, Vitor Mendes
Gralla, Jan
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Kaesmacher, Johannes
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Fahed, Robert
Piotin, Michel
Cognard, Christophe
Additional Credits
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Series
Scientific Reports
Publisher
Nature Publishing Group
ISSN
2045-2322
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo